Kontron Solar GmbH, formely known as Steca Elektronik GmbH

StecaGrid - Model 1800 - Grid Inverters Brochure

DC circuit breakerStecaGrid ALD1Digital energy meter 71 176243StecaGrid 300StecaGrid 500StecaGrid 300 and StecaGrid 500The inverters series comprises the StecaGrid 300 and StecaGrid 500 inverters, with rated outputs of 300 W and 500 W, respectively. StecaGrid 300 and StecaGrid 500 are built in a modular manner, and simple to install. With distribution over three phases, the system can at any time be expanded as desired, and thus flexibly adapts to your solar power system investment. StecaGrid 300 and StecaGrid 500 have an independent MPP tracker and achieve a very high effi-ciency of up to 95.8 %. Product features · Flexible and expandable · High efficiency · Low weight · Simple installation · Wall-mounting with top-hat railDisplays · Multi-coloured LED shows operating statusOptions · United Kingdom variants as per G83 available · Italy variants available · Spain variants availableSystem monitoring and accessoriesSTECAGRID 300 / 500 www.steca.comStecaGrid 300 StecaGrid 500DC input side (PV-generator)Maximum start voltage 135 V 230 VMaximum input voltage 135 V 230 VMinimum input voltage 45 V Minimum input voltage for rated output 64 V 106 VMPP voltage 45 V ... 100 V 45 V ... 170 VMaximum input current 5 AMaximum input power at maximum active output power 320 W 530 WMaximum recommended PV power 375 Wp 625 WpAC output side (Grid connection)Grid voltage 185 V … 276 V (depending on regional settings)Rated grid voltage 230 VMaximum output current 1.5 A 2.17 AMaximum active power (cos phi = 1) 300 W 500 WRated power 300 W 500 WRated frequency 50 HzFrequency 47 Hz ... 52 Hz (depending on regional settings)Night-time power loss 0 WFeeding phases single-phaseDistortion factor (cos phi = 1) < 6 % (max. power) < 5 % (max. power)Power factor cos phi 1Characterisation of the operating performanceMaximum efficiency 94.8 % 95.8 %European efficiency 93.4 % 94.5 %MPP efficiency 99 %Power derating at full power from 40 °CStandby power 0 WSafetyIsolation principle no galvanic isolation, transformerlessGrid monitoring version StecaGrid 300 UK resp. 500 UK voltage (230 V +15 %/-10 %)frequency (50 Hz +0.5 Hz/-3 Hz)voltage (230 V +15 %/-10 %)frequency (50 Hz +0.5 Hz/-3 Hz)Grid monitoring version StecaGrid 300 ES resp. 500 ES voltage (230 V +10 %/-15 %)frequency (50 Hz +/-1 Hz)voltage (230 V +10 %/-15 %)frequency (50 Hz +/-1 Hz)Grid monitoring version StecaGrid 300 IT resp. 500 IT voltage (230 V +/-20 %)frequency (50 Hz +/-0.3 Hz)voltage (230 V +/-20 %)frequency (50 Hz +/-0.3 Hz)Operating conditionsArea of application indoor rooms, with or without air conditioningAmbient temperature -20 °C ... +45 °CRelative humidity 0 % ... 95 %Noise emission < 32 dBAFitting and constructionDegree of protection IP 20Overvoltage category IIDC Input side connection Multi-Contact MC 3, MC 4AC output side connection Stecker Wieland Electric GST 18i3VDimensions (X x Y x Z) 176 x 243 x 71 mmWeight 1.4 kgCommunication interface noIntegrated DC circuit breaker noCooling principle natural convectionTest certificate CE mark, DK 5940, G83, RD1663 STECAGRID 300 / 500
Most popular related searches

Contact supplier

Drop file here or browse