Tedom Schnell GmbH

Technical Data Gensets 4.3

20111004 A007 technical data gensets 1500 Umin V4_4 biogas BRv.doc 2 all engines on Daewoo- Doosan basis. 3 acc. DIN 3046, min Hu: 5,2 kWh/m3N = 50% CH4 4 6 cylinder with single bearing alternator fixed coupled 5 Tolerance th. Power +- 8% 6 if used oxicat available as option, gas conditioning nec. A = dimension value; G = garantied; R = base value; L = Limit, engine can be operated till limit without change(eg.: load reduction, Power adaption above 400m a.s.l.) 1 type declaration: BGA = BioGasAggregat; 086= 08 ltr. displacement 6 cylinder; 158= 15 ltr. + 8 Zyl. aso. EHE: Exhaust Heat Exchanger, SCW: Secundary coolant water circuit 8 by use of EHE. 9 Scope of supply 1 Technical changes without notification. Last print: 2012-05-04 Genset/CHP Typ1 BGA086 BGA126 BGA158 BGA180 BGA222 BIOGAS 50% CH4 DLG TEST el. power @ cos j 1 kWel G 135 195 265 330 380 Alternator Leroy Typ : LSA 400V, 50 Hz, IP23 44.2L12 46.2L9 47.2S4 47.2M7 47.2M7 Efficiency @ 4/4 load % G 94,7 95,4 96 96,2 96,2 Nom. current @ cos j 1 A R 195 286 382 476 548 Insulation / max. Temp L H / 40°C H / 40°C H / 40°C H / 40°C H / 40°C efficiencies Effectiv / electric G 39 / 37,5 41,8 / 39,9 41,1 / 39,5 41 / 39,5 41,7 / 40,2 thermal power5 without EHE kW R 60 75 90 100 120 Thermal140°C exhaust temp. kW R 140 200 266 320 365 el./th. ratio @ 140°C R 0,96 0,98 1,0 1,03 1,04 heating, FW/BW Temp.8 °C A 70/90 65/85 70/90 70/90 70/90 Volumeflow m3/h R 9,5 11,2 16 18 21 Perm. press. drop SCW Mbar R 300 300 300 300 300 min. volume flow GMK (?T) m³/h R 14 (2,5°K) 18 (2,5°K) 25 (2,5°K) Max. pressure drop GMK mbar R 120 120 100 leanburn biogas engine (NOx:500; CO:1000 mg/mN³ @ 5% O2, 60 mg/m³N Formaldehyd) PU086 PU126 GV158 GV180 GV222 Nom power engine (ICFN)2 kWm G 143 204 278 343 395 Construction A 6R 111x139 6R 123x155 8V 128x142 10V 128x142 12V 128x142 Displacement Ltr. A 8,07 11,05 14,62 18,26 21,91 Speed min-1 A 1500 1500 1500 1500 1500 MEP bar A 14,1 14,8 15 15 14,4 Consumption Prime energy consumption3 (+5% tolerance) 100 % load kW G 375 488 672 840 950 Gasconsumption@ 50% CH4 m3N/h R 76 101 136 171 192 Exhaust mass flow kg/h A 845 1160 1510 1900 2200 Lube oil consumption (after 1000h @ PN, wo oilchange ± 20% tolerance) g/ kWh R 0,3 0,3 0,3 0,3 0,3 Standard scope of supply • Genset with 2 bearing alternator4 flexible coupled. • completely elastic mounted on welded base frame. • el. driven engine coolant pump with internal thermostat valves • primary coolant compl. mounted • baseframe on sylomer stripes • power switch cabinet complete wired and mounted on base frame • Gas supply chain with mangentic double valve, flame arrestor, leackage control, zero pressure regulator and flexible hose for roof or wall mounting • El. ignition system, carburator, mixture control (AFR), airfilter– all complete mounted and proofed Switch cabinet IntellySys PLC Options • single parallel mode, remote control Analog or ISDN or DSL modem: Standard: GPRS • 8” TFT graphical display, engine monitoring and monitoring auxillaries, auxillaries drive and control • start, stop synchronize, load control, air/fuel control, external contacts, remote start. • all analog and binary signals on display. • GPRS control in scope of supply. • digital speed control, high voltage ignition system Altronic, DetCon • well sized main generator circuit breaker • Gas and smoke sensor • single cyl. Temp control, monitoring • Mains circuit breaker for Island mode (customers load shedding necessary; may be delivered by agrogen) • on demand: web-based fleet management via GreenGuard; monthly additional cost for user access • components available in 45dB@10m version • FU controlled speed for LT & HT radiator • scope of supply also available in 65dB steel container or 45dB concrete container design 20111004 A007 technical data gensets 1500 Umin V4_4 biogas BRv.doc 2 all engines on Daewoo- Doosan basis. 3 acc. DIN 3046, min Hu: 5,2 kWh/m3N = 50% CH4 4 6 cylinder with single bearing alternator fixed coupled 5 Tolerance th. Power +- 8% 6 if used oxicat available as option, gas conditioning nec. A = dimension value; G = garantied; R = base value; L = Limit, engine can be operated till limit without change(eg.: load reduction, Power adaption above 400m a.s.l.) 1 type declaration: BGA = BioGasAggregat; 086= 08 ltr. displacement 6 cylinder; 158= 15 ltr. + 8 Zyl. aso. EHE: Exhaust Heat Exchanger, SCW: Secundary coolant water circuit 8 by use of EHE. 9 Scope of supply 2 Technical changes without notification. Last print: 2012-05-04 Noise Standard LU9, super silent on request BGA086 BGA126 BGA158 BGA180 BGA222 Exhaust in 1m / 10m dB(A) A 85 / 65 85 / 65 85 / 65 85 / 65 85 / 65 Air In/ outlet in 1m / 10m dB(A) A 82 / 62 85 / 65 82 / 62 85 / 65 85 / 65 Gascompressor in 1m / 10m dB(A) A 76 / 56 76 / 56 78 / 58 78 / 58 78 / 58 HT Radiator in 1m / 10m dB(A) A 68 / 48 79 / 59 77 / 57 77 / 57 77 / 57 LT Radiator in 1m / 10m dB(A) A n.v. n.v. 68 / 48 68 / 48 68 / 48 Super silent LU9 BGA086 BGA126 BGA158 BGA180 BGA222 Exhaust in 1m / 10m dB(A) A 65 / 45 66 / 45 60 / 41 60 / 41 61 / 42 Air In/ outlet in 1m / 10m dB(A) A 68 / 49 70 / 50 70 / 50 70 / 50 70 / 50 Gascompressor in 1m / 10m dB(A) A 64 / 44 64 / 44 66 / 46 66 / 46 66 / 46 HT Radiator in 1m / 10m dB(A) A 65 / 45 65 / 45 63 / 43 63 / 43 65 / 45 LT Radiator in 1m / 10m dB(A) A n.v. n.v. 63 / 43 59 / 40 59 / 40 Optional scope of supply Exhaust system (diameter BGA V engines: DN150; R engines: DN100) Gaspressure blower Including or without exhaust heat exchanger: • 12 m exhaust system with pipe, holder, bellows, ellbows, insulation, silencer. Completely premounted • Sidechannel blower with bypass. On request with frequency control. • Gascooling and condensate separation system, active coal filter. (Condition when Oxicat for 40mg H2CO is used) lube oil system LT Mixture coolant circuit5 • Automatic via pump. control with min/max sensor • Pump with 2 directions for used oil dispump • Contains: pump, 3-way valve, safety instruments, expansion vessel, sensors, LT radiator 40kW, Inline engines: Front radiator used with bellow to air outlet silencer Air supply HT secundary coolant circuit5 • Intake air system with silencer, speed controlled fan, 3-phase, 400 V, room temp control, air outlet silencer • Contains: pump, 3-way valve, safety instruments, expansion vessel, sensors, HT radiator Single cylinder temperature control Oilseparator • 1 thermocouple per cylinder, AD converter for InteliSys; display with bargraph; warning and alarm function • 2 stage cyclon separator. Also for post installation to crankcase. Increases oil intervall. Complete scope of supply in Container housing Oxicat • Complete CHP system with accessory mounted in sound proofed container. Standard noise: 65dB(A) in 10m, up to 55dB(A) possible. <55dB concrete housing available • Oxicatalyzer for decreasing H2CO below 40mg 5 Inline engines with front radiator 20111004 A007 technical data gensets 1500 Umin V4_4 biogas BRv.doc 2 all engines on Daewoo- Doosan basis. 3 acc. DIN 3046, min Hu: 5,2 kWh/m3N = 50% CH4 4 6 cylinder with single bearing alternator fixed coupled 5 Tolerance th. Power +- 8% 6 if used oxicat available as option, gas conditioning nec. A = dimension value; G = garantied; R = base value; L = Limit, engine can be operated till limit without change(eg.: load reduction, Power adaption above 400m a.s.l.) 1 type declaration: BGA = BioGasAggregat; 086= 08 ltr. displacement 6 cylinder; 158= 15 ltr. + 8 Zyl. aso. EHE: Exhaust Heat Exchanger, SCW: Secundary coolant water circuit 8 by use of EHE. 9 Scope of supply 3 Technical changes without notification. Last print: 2012-05-04 Rated power BGA086 BGA086-90 BGA086-100 BGA086-110 BGA086-120 BGA086-130 el. power kWel. G 90 100 110 120 130 Prime power kW R 264 283 302 325 351 Rated power BGA126 BGA126-140 BGA126-150 BGA126-160 BGA126-170 BGA126-180 el. power kWel. G 140 150 160 170 180 Prime power kW R 400 410 420 439 461 Rated power BGA158 BGA158-210 BGA158-220 BGA158-230 BGA158-240 BGA158-250 el. power kWel. G 210 220 230 240 250 Prime power kW R 589 586 598 618 641 Rated power BGA180 BGA180-280 BGA180-290 BGA180-300 BGA180-310 BGA180-320 el. power kWel. G 280 290 300 310 320 Prime power kW R 800 805 798 806 820 Rated power BGA222 BGA222-330 BGA222-340 BGA222-350 BGA222-360 BGA222-370 el. power kWel. G 330 340 350 360 370 Prime power kW R 942 944 932 936 948 BGA044 BGA086 BGA126 BGA158 BGA180 BGA222 LBH (L: with pumpsystem) m A 2,0x1,1x1,5 2,8x1,5x1,7 3,3x1,6x1,7 3,7x1,5x1,8 4,0x1,5x1,9 4,1x1,5x1,9 mass (empty) kg A 1240 1750 2200 2980 3740 4050 agrogen GmbH • Energiepark 4 • D-91732 Merkendorf Tel. +49 9826 / 6585 0 • Fax +49 9826 / 6585 200 • info@agrogen.eu • www.agrogen.eu Service hotline:+49 9826 / 6585 100
Most popular related searches

Contact supplier

Drop file here or browse