Dmsolar, LLC
- Home
- Companies & Suppliers
- Dmsolar, LLC
- Downloads
- TR3624 Specifications Sheet
TR3624 Specifications Sheet
Smart choice for power©2009 Xantrex Technology Inc. All rights reserved. Xantrex is a trademarks of Schneider Electric Services International sprl, registered in the U.S. and other countries.Modified sine wave inverter/chargerXantrex Technology Inc.Headquarters8999 Nelson WayBurnaby, British ColumbiaCanada V5A 4B5+1 800 670 0707 Toll Free+1 604 420 1591 FaxEuropeXantrex Technology GmbHSteinheimer Str. 11763500 Seligenstadt, Germany+49 (0) 6182 81 6000 Tel+49 (0) 6182 81 6001 FaxXantrex Technology S.L.Bac de Roda, 52 edificio A08019 Barcelona, Spain+34 93 433 8350 Tel+34 93 433 8351 Faxeuropesales@xantrex.comwww.xantrex.comOur evolution to Schneider Electric, the global specialist in energy management, re-affirms our commitment to provide you with innovative solutions, best-in-class customer service, and exceptional quality in everything we do. We are proud to be your partner, and we are dedicated to helping you make the most of your energy.Xantrex™ Trace SeriesInverter/Charger120 Vac/60 Hz models230 Vac/50 Hz modelsBased on the proven technology of the Xantrex™ DR Series, the Xantrex™ Trace Series Inverter/Charger is an economical power conversion solution designed to provide dependable modified sine wave electricity to essential circuits in the home or business during a power outage. It can also be used in conjunction with a generator or any renewable energy source in an off-grid application. In addition to providing new features, the Trace Series improves on the key features that have made the DR Series the most robust and reliable inverter/charger line for backup power and off-grid applications. Features New digital display shows kilowatts (kW) when inverting and amps (A) when charging, plus incorporates a robust ON/OFF membrane switch and status indicators New power factor corrected (PFC) charging, combined with a more sophisticated multi-stage battery charging algorithm, reduces electricity draw and generator run-time Simplified controls with a snap-on cover that protects settings from being accidentally changed Better thermal performance allows full output power to 50°C (122°F) without de-rating High surge capacity starts more difficult loads and handles overload conditions reliably Circuit boards are conformally-coated to protect them from corrosion for longer life & improved reliability Durable powder coated, corrosion resistant steel chassisOptions TR-Remote On/Off Switch – includes LED status indicator (P/N: 989-1060) TR-Conduit Box – connects to the DC side of the inverter and accepts ¾”, 1” or 2” conduit (P/N: 989-1050)©2009 Xantrex Technology Inc. All rights reserved. Xantrex is a trademarks of Schneider Electric Services International sprl, registered in the U.S. and other countries.Electrical SpecificationsPart number 989-1000 989-1010 989-1005 989-1015 989-1020 989-1025 989-1030 989-1035Model number TR1512-120-60 TR2412-120-60 TR1524-120-60 TR2424-120-60 TR3624-120-60 TR1512-230-50 TR1524-230-50 TR2424-230-50Invert mode: Waveform Modified sine wave Modified sine wave Modified sine wave Modified sine wave Modified sine wave Modified sine wave Modified sine wave Modified sine waveContinuous output power 1500 VA 2400 VA 1500 VA 2400 VA 3600 VA 1500 VA 1500 VA 2400 VAAC output voltage (rms) 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 230 Vac 230 Vac 230 VacAC output frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 50 Hz 50 Hz 50 HzRated AC output current 12.5 Aac 20 Aac 12.5 Aac 20 Aac 30 Aac 6.5 Aac 6.5 Aac 10.4 AacSurge capability Max. Output & Duration: Overload 10 sec rating 3000 VA 4800 VA 3000 VA 4800 VA 7200 VA 3000 VA 3000 VA 4800 VA Short Circuit 10 sec rating 50±5 Apk 80±8 Apk 50±5 Apk 80±8 Apk 120±12 Apk 26.5±2.5 Apk 26.5±2.5 Apk 42±4 ApkAdjustable load sensing range 5 watts minimum to 240 watts maximum 10 watts minimum to 480 watts maximumDC input current at no load - search mode 0.35 amps 0.35 amps 0.17 amps 0.17 amps 0.20 amps 0.35 amps 0.20 amps 0.20 ampsEfficiency - peak > 90% > 92% > 92% > 93% > 94% > 92% > 91% > 94%DC input voltage range 11.0 - 15.0 Vdc 11.0 - 15.0 Vdc 22.0 - 30.0 Vdc 22.0 - 30.0 Vdc 22.0 - 30.0 Vdc 11.0 - 15.0 Vdc 22.0 - 30.0 Vdc 22.0 - 30.0 VdcRated DC input current 157 amps 252 amps 76 amps 120 amps 186 amps 158 amps 77 amps 121 ampsLoad power factor (allowed) 0.8 to 1.0 (leading or lagging) 0.8 to 1.0 (leading or lagging)Series operation Yes - Two units can be connected to produce 120/240 Vac split phase power, stacking cable included No No NoBypass / Charge mode:AC input voltage range 65 - 140 Vac (wide), 95 - 140 Vac (narrow) 120 - 253 Vac (wide), 180 -253 Vac (narrow)AC input frequency range 55 - 64 Hz (narrow-charge & pass-through), 45 - 55 Hz (narrow-charge & pass-through), 55 - 68 Hz (wide-charge), 41 - 68 Hz (wide pass-through) 45 - 68 Hz (wide-charge), 41 - 68 Hz (wide pass-through)Built-In internal supplemental breakers 30 Aac bypass, 30 Aac bypass, 30 Aac bypass, 30 Aac bypass, 30 Aac bypass, 15 Aac bypass, 15 Aac bypass, 15 Aac bypass, 20 Aac charger 30 Aac charger 20 Aac charger 30 Aac charger 30 Aac charger 8 Aac charger 8 Aac charger 15 Aac chargerDC charger rate (adjustable) 10 - 70 amps 14 - 100 amps 5 - 35 amps 10 - 70 amps 10 - 70 amps 10 - 70 amps 5 - 35 amps 10 - 70 ampsAC input current at max. charge rate 11.2 Aac 15.8 Aac 10.2 Aac 19.7 Aac 19.5 Aac 5.9 amps 6.0 amps 10.4 ampsAC input power factor 0.88 0.89 > 0.88 0.92 0.93 0.91 > 0.83 0.92Multi-stage charging Yes - bulk, absorption and float, plus Yes - bulk, absorption and float, plus user-initiated equalize (for flooded batteries only) user-initiated equalize (for flooded batteries only)Temperature compensation Battery temperature sensor included Battery temperature sensor included Automatic transfer relay 30 amps 30 amps 30 amps 30 amps 30 amps 15 amps 15 amps 15 amps Transfer time (typical) < 40 ms (wide), < 20 ms (narrow) < 40 ms (wide), < 20 ms (narrow) Environmental Specifications Dimensions (W x H x L) 8.5 x 7.25 x 21” (216 x 184 x 546 mm) Weight 40 lbs (18 kg) 42 lbs (19 kg) 40 lbs (18 kg) 45 lbs (20 kg) 45 lbs (20 kg) 42 lbs (19 kg) 42 lbs (19 kg) 42 lbs (19 kg)Shipping Dimensions (W x H x L) 12.4 x 11.8 x 26.6” (315 x 300x 675 mm) Shipping Weight 50 lbs (22.7 kg) 52 lbs (23.6 kg) 50 lbs (22.7 kg) 55 lbs (24.9 kg) 55 lbs (24.9 kg) 52 lbs (23.6 kg) 52 lbs (23.6 kg) 52 lbs (23.6 kg)Operating temperature range 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CMounting Wall-mount (with 16” mounting centers) Wall-mount (with 16” mounting centers)Warranty Two years Two years Two years Two years Two years Two years Two years Two years Regulatory ApprovalsCSA Certified to CSA 107.1, UL1741, FCC Class B and Industry Canada, CESpecifications subject to change without notice.Modified sine wave inverter/chargerXantrex™ Trace Series Inverter/Charger
Most popular related searches