MWA Technology
- Home
- Companies & Suppliers
- MWA Technology
- Downloads
- Turbine Energy Meters Brochure
Turbine Energy Meters Brochure
w w w . i t r o n . c o mHeat> Integral-V MaXXIntegral-V MaXXCompact heat meter Qn 0,6 / 1,5 / 2,5The Itron Compact heat meter Integral-V MaXX for allocation and billing is a high performance response to the markets needs.Compact dimensions and high flexibility of options are strengths of Integral-V MaXX.MID approval heat meterThe heat meter is MID approval with a dynamic range Qi : Qp of 1:100. The flow sensor meets all requirements of AGFW (German association of district heating companies) in terms of accuracy and durability.Proven electronic turbine detection The patented electronic detection system guarantees a reactionless transmission of volume pulses to the calculator.Advanced functionsThe calculator is ASIC controlled and displays all actual and fixed date related data, ergonomically operated by one push button.Pre-equipped for future communicationAll Integral-V MaXX meters are preequipped to be connected to several types of option connectors, such as an option plug for M-BUS communication> Pre-equipped for connection of water meters with pulse output> Pre-equipped for energy and volume repetition outputCE type approval certificate:DE-06-MI004-PTB003HeatDimensionsIntegral-V MaXXPressure lossLCDThe different displays can be selected by one single push button. Keeping the push button pressed (appr. 3s) the LCD switches into 2nd LCD level. Additional displays are available after connection of option connectors.Multifunctional Displayfor visualisation of relevant data:> Level 1- Energy- Volume- LCD test- Energy and date of past 13 months> Level 2- Actual flow- Temperature difference- Supply temperature- Return temperature- Time in error (hours)- Operation time (Years, days)- Firmware version> Optional- Primary address (M-Bus)- Secondary address (M-Bus)- Volume of connected water metersPush buttonLCDCoils for turbine detectionTurbineQn 1.5 DN 15Qn 0,6Qn 2.5 DN 200.010.020.030.050.10.20.30.51.00.1 0.2 1.0 2.0 10flow (m3/h)pressure loss (bar)Technical dataInstallation KitsType INTEGRAL-V MaXX INTEGRAL-V MaXX INTEGRAL-V MaXXQn 0,6 Qn 1,5 Qn 2,5Labels in English Reference 4051233037 4055233037 4056233037Labels in German Reference 4051231037 4055231037 4056231037CalculatorTemperatur range T °C 20…9020…140 (option)20…9020…140 (option)20…9020…140 (option)Temperature difference dT: °C 3…703…120 (option)3…703…120 (option)3…703…120 (option)Resolution of LCD KWhm30…99999990…99999,990…99999990…99999,990…99999990…99999,99Lithium Battery Voltage VLifetime3,610 years3,610 years3,610 yearsProtection Class IP 54 54 54Environmental Class EN1434 C - M1 - E1 C - M1 - E1 C - M1 - E1Flow SensorNominal Size DN mm 15 15 20Nominal Flow rate Qp m3/h 0,6 1,5 2,5Dynamic range PTB H : 1:100 / V : 1:50 H/V : 1:100 H/V : 1:100Max. Flow (short time) Qs m3/h 1,2 3,0 3,0Minimum Flow rate Qi l/h 6 15 25Temperature range Tvmt °C 20-90°C 20-90°C 20-90°COperating pressure PN bar 16 16 16Connection G 3/4 A G 3/4 A G 1 ALength mm 110 110 130Weight kg 0,55 0,55 0,65Temperature SensorTechnology PT100 PT100 PT100Type Pocket Ø 6mm x 50mm Ø 6mm x 50mm Ø 6mm x 50mmType of Connection 2-wires 2-wires 2-wiresCable length Spiral cable 1,2m 1,2m 1,2mOther sensors on requestType EBS-3/4”-K EBS-1”-K EBS-3/4”-KH EBS-1”-KHReference 2434000006 2422000006 2433000006 2423000006Length without valves mm 110 130 110 130Length incl. valves mm No valves No valves 200 230T-pipe for supply sensor 3/4’’ x 40mm 1’’ x 50mm 3/4’’ x 40mm 1’’ x 50mmInstallation kits for direct immersion sensor on requestAbout Itron Inc.Itron Inc. is a leading technology provider to the global energy and water industries. Our company is the world’s leading provider of metering, data collection and utility software solutions, with nearly 8,000 utilities worldwide relying on our technology to optimize the delivery and use of energy and water. Our products include electricity, gas and water meters, data collection and communication systems, including automated meter reading (AMR) and advanced metering infrastructure (AMI); meter data management and related software applications; as well as project management, installation, and consulting services. To know more, start here: www.itron.comFor more information, contact your local sales representative or agency.© Copyright 2010, Itron. All Rights Reserved. - Itron reserves the right to change these specifications without prior notice.Allmess GmbHAm Voßberg 1123758 Oldenburg i.H.DeutschlandTel: 0 43 61/62 5-0Fax: 0 43 61/62 5 -250www.itron.comHE-0010.0-EN-09.10OptionsAll Integral MaXX meters are prepared to be connected to different types of option connectors.The meter detects automatically the connected option and provides the additional functions.Option connectors can be plugged even on site without breaking metrological seals.The M-Bus option allows the remote reading of all relevant data according to the European heat meter standard EN1434-3. Up to 250 meters can be connected to a concentrator or repeater. The data can be transferred through standardized serial interface (RS232) to the processing unit (e.g. Windows PC). In addition it is possible to connect the concentrator to a modem for remote reading via telephone network.Up to 4 water meters with pulse output can be connected to Integral MaXX. This allows the reading of actual and fixed date consumption values of the connected water meters on LCD or through M-Bus.The pulse output option transmits energy and volume proportional pulses to a counting unit.Type Option connector M-BUS & 4 water metersReference 4097000037M-Bus specificationProtocol EN1434-3, variable protocol low byte first.Baudrate 300 or 2400 Baud (programmable by M-Bus).Data (standard frame) Energy, volume, flow, temperatures (supply, return, delta), time in error,operating time, date & time, volume of connected water meters 1…4,version of firmware.Data(13 monthly fixed date frames)Energy of the heat meter, volume of all connected water meters and date of the fixed date. 13 different frames (13 lpast month) selectable by MBus.Water meters pulse input specification (for reed switches or equivalent switches)Pulse weight 10 liter or 100 liter per pulse (programmable by M-Bus or push buttonDetection voltage typical 3VPulse detection Contact closed R = 500 OContact open R = 100 kOPulse/pause ratio: =3 sec.Maximum wire length 30mType Option connector Repetition energy and volumeReference 4098000037Max. detection voltage 30 VMax. current 20 mAMax. output resistance R on 100 O (during repetition pulse)Pulse width 500msPulse weight Energy: 1 kWhVolume: 10 L
Most popular related searches
