Power Electronics S.L.
  1. Companies & Suppliers
  2. Power Electronics S.L.
  3. Downloads
  4. V2 Series - Electronic Softstarters - ...

V2 Series - Electronic Softstarters - Brochure

Easy to driveReadyListoFertigRunMarchaLäuftOL warning/UL faultAviso sobrecarga/Fallo subcargaÜberlast warnung/Unterlast FehlerOverloadSobrecargaÜberlastOvertemperatureSobretemperaturaÜbertemperatureGeneral faultFallo generalFehler304100157350132DT0054364100157132410DT0092ReadyListoFertigRunMarchaLäuftOL warning/UL faultAviso sobrecarga/Fallo subcargaÜberlast warnung/Unterlast FehlerOverloadSobrecargaÜberlastOvertemperatureSobretemperaturaÜbertemperatureGeneral faultFallo generalFehlerAs well as the total protection provided to the motor, the smooth start and stop action offered by the V2 has benefited numerous applications.Pumps, fans, conveyors, compressors, shakers, mixers, grinders, crushers, lifters, crains, elevators, etc. are some examples of the V2 Series applications. The V2 Series is part of the Power Electronics soft starter family. Equipped with advanced technology in motor control and protection, the V2 has been designed in a more compact form, unifying spare parts and giving the flexibility of installation in both IP00 and IP54 versions.Note: The references signed with (*) do have an integrated BYPASS function. The motor protection is operating all the time.230V to 400V (±10%)FRAME CODE I(A)RatedPOWER (Kw) at 230VPOWER (Kw) at 400VDIMENSIONS(mm)IP PROTECTION1V2009 9 2.2 4 350x157x132 IP00V2017 17 4 7,5 350x157x132 IP00V2030 30 9 15 350x157x132 IP00V2045 45 15 22 350x157x132 IP00V2060* 60 18.5 30 350x157x132 IP00V2075* 75 22 37 350x157x132 IP00V2009B* 9 2,2 4 350x157x132 IP54V2017B* 17 4 7,5 350x157x132 IP54V2030B* 30 9 15 350x157x132 IP54V2045B* 45 15 22 350x157x132 IP542V2060B* 60 18.5 30 410x157x132 IP54V2075B* 75 22 37 410x157x132 IP54> dimensions and standard ratingsV2 SERIESFRAME 1IP00: V2009 - V2075IP54: V2009B - V2045BFRAME 2IP54: V2060B - V2075BINPUT Input voltage 230 - 400V(~3 phases), ±10%Frequency 47 - 62 HzControl voltage 230V ±10%, others under demandOUTPUT Output voltage 0 - 100% of input voltageOutput frequency 47 - 62 HzEfficiency (at full load) > 99%ENVIRONMENTALCONDITIONSAmbient temperature Operation: 0°C to +40°C. Without BypassOperation: 0°C to +50°C. With built in BypassStorage: -10°C to +70°CAltitude de-rating >1000m 1% per 100m, maximum 3000mHumidity 95% at 40°C non-condensingProtection degree IP00; IP54Cooling NaturalMOTORPROTECTIONSInput phase lossStarting current limitRotor lockedMotor overload (thermal model)UnderloadPhases imbalanceV2 PROTECTIONS General faultV2 overtemperatureSETTINGS Initial torque 30 to 99%Acceleration ramp 0 to 15 secDeceleration ramp 0 to 45 secOverload 0.8 to 1.2 InOverload curve 1 to 10Underload 0.2 to 0.6 InUnderload curve 1 to 10Current limit 1 to 5 InAUXILIARY CONTACTS 2 change over relays 5A, 230Vac Fault relayInstantaneous relayLED’S INDICATION LED 1 ReadyLED 2 StartLED 3 Overload warning / Underload faultLED 4 OverloadLED 5 OvertemperatureLED 6 General faultELECTRIC SAFETYREGULATIONSUNE-EN 60947-4-2:98 UNE-EN 60204-1:1999UNE-EN 50178:98 UNE-EN 50081-1:94> power electronics & control wiringV2 SERIES> technical specificationsV2 SERIES*Note: Minimum protection recommended for F1, 1A.L1L2L3NPEPEQ0F1*L N.C. NL1L2L3NPE230VacL1 L2 L3 PEPEU V WU1 V1 W1PE~M312V2DT0045C1 2 3 4 5 6 7 8 9 10 11 12 13LN230VacDIGITAL OUTPUTSFAULTRELAYINSTANTANEOUSRELAYDIGITAL INPUTSStopStartResetStart PulseStart / StopDT0038EIPOWER ELECTRONICS reserves the right to modify whole or part of the content of this brochure at any time and without prior notice. March 2007.V2CA01GIHEAD OFFICE ? ???BRANCHESSPAINLeonardo da Vinci, 24 - 26Parque Tecnológico46980 • PATERNAVALENCIA • ESPAÑATel. 902 40 20 70Tel. (+34) 96 136 65 57Fax (+34) 96 131 82 01AUSTRALIAPower Electronics Australia Pty Ltd U6, 30-34 Octal St, Yatala,BRISBANE, QUEENSLAND 4207P.O. Box 3166,Browns Plains, Queensland 4118 •AUSTRALIA Tel. (+61) 7 3386 1993Fax. (+61) 7 3386 1997 BRAZILPower Electronics Brasil Ltda Av. Guido Caloi, 1985 - Galpão 09CEP 05802-140 SÃO PAULO • BRASILTel. (+55) 11 5891 9612Tel. (+55) 11 5891 9762CHILEPower Electronics CHILE Ltda Los Productores # 4439 - HuechurabaSANTIAGO • CHILE Tels. (+56) 2 244 0308 - 0327 - 0335Fax. (+56) 2 244 0395Oficina Petronila # 246, Casa 19 ANTOFAGASTA • CHILE Tel. (+56) 55 793 965CHINAPower Electronics BEIJING Room 509, Yiheng Building, No. 28 East Road, Beisanhuan100013, Chaoyang DistrictBEIJING • P.R. CHINA Tel. (+86) 10 6437 9197Fax. (+86) 10 6437 9181Power Electronics Asia Limited20/F Winbase Centre 208 Queen’s Road Central HONG KONG • P.R. CHINAGERMANYPower Electronics Deutschland GmbH Dieselstraße, 7790441 NÜRNBERG • GERMANY Tel. (+49) 911 99 43 99 0Fax. (+49) 911 99 43 99 8INDIAPower Electronics IndiaNo. 26, 3rd Cross.VishwanathapuramMADURAI - 625014Tel. (+91) 452 434 7348Fax. (+91) 452 434 7348KOREAPower Electronics Asia HQ Co. Room #305, SK Hub Primo Building953-1, Dokok-dong, Gangnam-gu SEOUL, 135-270 • KOREATel. (+82) 2 3462 4656Fax. (+82) 2 3462 4657MEXICOPower Electronics Internacional México S. de R.L. de C.V.José Vasconcelos, 9Colonia Tlalnepantla Centro Tlalnepantla de Baz CP 54000, Estado de México Tel. (+52) 55 5390 8818Tel. (+52) 55 5390 8363Tel. (+52) 55 5390 8195www.power-electronics.com
Most popular related searches

Contact supplier

Drop file here or browse