Continental Control Systems, LLC (CCS), A member of Socomec Group

WattNode Logger for LonWorks Datasheet

Continental Control Systems LLCTHE WATTNODE® LOGGER for LonWorks® is a networked, multi-function digital energy meter with internal logging. The WattNode Logger offers true RMS power, energy and demand metering, plus individual phase measurements of voltage, current, power factor, reactive power and energy, and line frequency. The WattNode Logger can log 24,000+ measurement records in non-volatile memory. Typical applications include energy monitoring, sub metering, demand management and stand-alone electrical system data logging.NETWORKING for LonWorks is easy. A simple twisted-pair connection links all devices together into a LonWorks network. Measurements are transmit-ted over the network as Standard Network Variable Types (SNVTs).LOGGING is provided for all important measurements at user-selectable intervals from 1 minute to 12 hours. At a 15-minute interval, it can log for 250 days. Logging is possible in a networked or stand-alone mode. An LNS plug-in downloads the data to a PC file in CSV format. EASE OF USE and economy of installation were key design criteria. The WattNode Logger's compact size permits installation inside of most electrical service panels and junction boxes. Detachable screw terminals make wiring a snap. The WattNode Logger is line-powered and requires no separate power source.ACCURACY of the WattNode Logger is 0.5% nominal. Even with leading or lagging power factor and chopped or distorted wave forms, the WattNode Logger measures true RMS power. This makes it ideal for monitoring motors and pumps controlled by variable speed drives or loads with switching power supplies.THE COMPLETE LINE of WattNode Logger models measures 1, 2, or 3 phases in 2, 3, or 4 wire configura-tions with nominal voltages from 120 to 600 VAC at 50/60 Hz. Operation from 5 to 5000 Amps is possible by selecting from our line of safe, low-voltage output, current transformers. 3131 Indian Road, Suite ABoulder, CO 80301 USA(303) 444-7422 Fax (303) 444-2903sales@ccontrolsys.comwww.ccontrolsys.comToll-Free(888) 928-8663WATTNODE® LOGGER· Multiple MeasurementskW, kWh, Demand, kVAR, kVARh, PF, Amps, Volts, Frequency· Bidirectional MeteringEnables net metering solution for PV or wind turbine sites · LonWorks Network Ready Simple twisted-pair network installation, Internet accessible· LonMark Version 3.4 CertifiedEasy to integrate using an open, interoperable device · Measures 1Ø, 2Ø, 3Ø Circuits Flexible for various applications· Line Powered No external power supply required· Compact SizeFits inside of standard power panels and junction boxes AC Power Measurement for LONWORKS ®WattNode is a registered trademark of Continental Control Systems LLCLonMark, the LonMark logo and LonWorks are registered trademarks of Echelon CorporationKWH KVAR VOLTSContinental Control SystemsFREQUENCY PF AMPSA CTO /B CTO /C CTO /AO /BO /CO /NO /O / 240V240V240V CAT III240V CAT III120V120VService0.333VWatthour MeterUS LISTED 3KNN0.333V0.333VO /O /O /O /FT10WATTNODE® LOGGERContinental Control Systems LLCWNC-3Y-208-FT10120V 50-60Hz 3WSN 028122NI 0416A3CE0201KWPEAK DEMANDLOGGING Quantities Measured Energy: Real and reactive Power: Real and reactive, per phase and sum Voltage: Per phase volts Current: Per phase amps Frequency Power Factor: Per phase and average Demand: Block or sliding window Peak Demand: Value and time Quantities Logged Date & Time Net Energy (A, B, C & Sum) Reactive Energy (Sum) Positive Energy (Sum) Real and Reactive Power (A, B, C & Sum) Voltage, Current & Power Factor (A, B, C) Demand Measurement Configuration Three phase: 3-wire or 4-wire Single phase: 2-wire or 3-wire LonWorks Interoperability 40 network variables using Standard Network Variable Types (SNVTs) LonMark Version 3.4 User Controlled Inputs Set CT size in amps Set demand window type and period Reset peak demand to zero Set time of day Accuracy 0.5% nominal (see manual for details) Time: ± 2 minutes a year (battery backed) Electrical Operating Voltage Range: 80% - 115% of nominal Power Line Frequency Range: 50 to 60 Hz Environmental Temperature: -30 oC to 55 oC Humidity: 5 to 90% RH (noncondensing) Mechanical Enclosure: High impact, UL rated, ABS plastic Size: 3.3" x 5.6" x 1.5" (includes mounting tabs) Connectors: Detachable screw terminals (22-12 AWG)WATTNODE® LOGGERAC Power Measurement for LONWORKS ®Continental Control Systems3131 Indian Road, Suite ABoulder, CO 80301(303) 444-7422 Fax (303) 444-2903sales@ccontrolsys.comwww.ccontrolsys.comMODELSModel VAC VAC Phases Wires Line To Neutral Line To LineWNC-3Y-208-FT10-L 120 208-240 3* 4WNC-3Y-400-FT10-L 230 400 3* 4WNC-3Y-480-FT10-L 277 480 3* 4WNC-3Y-600-FT10-L 347 600 3* 4WNC-3D-240-FT10-L N/A 208-240 3 3WNC-3D-400-FT10-L N/A 400 3 3WNC-3D-480-FT10-L N/A 480 3 3*Can be used to measure 1, 2 or 3 phase circuits.OPENING CURRENT TRANSFORMERS (SPLIT CORE)Model Inside Diameter Rated AmpsCTS-0750 0.75" 5, 15, 30, 50, 70, 100, 150, 200CTS-1250 1.25" 70, 100, 150, 200, 250, 300, 400, 600CTS-2000 2.00" 600, 800, 1000, 1200, 1500CTB Bus Bar 600, 800, 1200, 2000, 3000 (custom)TOROIDAL CURRENT TRANSFORMERS (SOLID CORE)Model Inside Diameter Rated AmpsCTT-0300 0.30" 5, 15, 20, 30CTT-0500 0.50" 15, 20, 30, 50, 60CTT-0750 0.75" 30, 50, 70, 100CTT-1000 1.00" 50, 70, 100, 150, 200CTT-1250 1.25" 70, 100, 150, 200, 250, 300, 400Current Transformer Output Voltage: 0 - 0.333 VAC @ rated current(888) 928-8663CTCTCTPhase APhase BPhase CGroundLOAD LINELonWorks NetworkNeutralContinental Control Systems LLC277V277VO /O /B CTO / 0.333VC CTO / 0.333VA CTO / 0.333VServiceFT10WATTNODE® LOGGERBO /CO /NO / AO / 240V240V CAT III120VO /O /WNC-3Y-208-FT10-L120V 50-60Hz 3WSN 028123NI 0416A3CE0200MADE IN THE USASpecifications WNC_Lon_Logger_Data_Sheet_P1of2 copy WNC_Lon_Logger_Data_Sheet_P2of2 copy
Most popular related searches

Contact supplier

Drop file here or browse