Tyne`s Response Time Monitor is designed to measure the actuator response time from `Start` signal to `Feed back`. It also provides an alarm when the response time is over the limit. The circuit is designed with a hardware logic integrated circuit. No software is used. The display comprises four 7-segment LEDs to display from 0.01s to 99.99s. The setting is established using BCD switches with displayed numbers. Once the unit detects a Start pulse, it starts to count until the Stop pulse is received. The count is compared to the setting of a digital comparator. Once the count has exceeded the setting, the alarm trips and sends the output to the terminals.

Most popular related searches

Tyne Engineering`s Response Time Monitor can be used for critical or safety-related actuator response monitoring or as a delay-on timer. An example application is for testing the response time of the vent panel opening in the Power House Emergency Venting System in Nuclear Power Plants.

  • 6 Individual Channels
  • Mature hardware gate logic design, involves no programmable devices, and no software.
  • Each of 6 response time monitors is displayed in numerical form. Each Channel has numerical display for the elapsed time and status LED Indicators.
  • Redundant power supply with status indicator.
  • Alarm time can be set by digital BCD switches.
  • Timing Resolution : 0.01S (10mS)
  • Timing Accuracy : 0.01S(10mS)
  • EMC Qualification :
    • IEC 61000-4-2, Electrical Discharge Requirements
    • IEC 61000-4-3, Radiated Electromagnetic Field Requirement
    • IEC 61000-4-4, Electrical Fast Transient/Burst Requirements
    • IEC 61000-4-5, Surge Withstand
    • IEC 61000-4-6, Conducted RF Immunity
    • IEC 61000-4-8, Magnetic Field Immunity Test
    • IEC 61000-4-11, Voltage Dip, Dropouts, interrupts and voltage
  • Number of Channels: : 6
  • Mounting : Panel Mount, Overall dimension: 7” height X 13.5” width X 10” depth
  • Control Contacts (Alarm) : Dry NO contact, Contact rating 0.5/48VDC.
  • Input Contacts (Start/Stop/Reset) : Dry contacts, Contact Rating: 0.1A @12VDC.
  • Power Supply : 120VAC ± 10%, 60Hz ± 2Hz.
  • Power Consumption : <24VA.
  • Timing aging : ±0.05mS per year in 10-second range (±5ppm/Year Frequency aging Crystal used for timing)
  • Range : 0-99.99S
  • Alarm Setting : 1-99S, with 1 Second step.
  • Operating Temperature : 10-50 °C
  • Operating Humidity : Up to 90%