Komax - Model CT45 -Cable Tester
The intelligent and measurement-accurate CT45 cable tester is utilized in our test systems due to its advanced functions, testpoint management, and control. The CT45 cable tester, when used with the CS WIN nx® testing software, provides a comprehensive solution for testing electrical connections, components, optical fibers, and the presence and position of mechanical components. The test sequence in a controlled process and generates statistics for quality management.The CT45 cable tester can manage up to 8.192 test points, which can be increased to 16.384 by using two cable testers. It supports all types of test point cards and is capable of testing passive electrical components within the wire harness. The CT45 cable tester can perform a wide range of measurements, including short-circuit, connection, component, leak, fiber optic attenuation, color detection, B+ detection, and more. New functions can be added through firmware updates.
CT45
Metric
- Dimensions/height: 45 mm
- Width: 485 mm
- Dimensions/depth: 170 mm
- Weight: 1.45 kg
- Total power max.: 25 W
- Ambient temperature, operation min.: 10 °C
- Ambient temperature, operation max.: 40 °C
- Ambient temperature, storage min.: -10 °C
- Ambient temperature, storage max.: 60 °C
- Air humidity non-condensing min.: 40 %
- Air humidity non-condensing max.: 75 %
- Protection class: 20
- Operating height (feet above sea level) max.: 2000 m
- Test voltage (AC) max.: 5 V
- Test voltage (DC) min.: 20m V
- Test voltage (DC) max.: 15 V
- Test current (DC) max.: 122.5 mA
- Test points, internal max.: 128
- Test points, total max.: 8192
- Continuity test via threshold identification min.: 20 Ω
- Continuity test via threshold identification max.: 10 kΩ
- Tolerance continuity test, +/- max.: 2 %
- Short-circuit test via threshold identification min.: 10 kΩ
- Short-circuit test via threshold identification max.: 1 MΩ
- Accuracy short-circuit test, +/- max.: 5 %
- Switch test min.: 20 Ω
- Switch test max.: 10 kΩ
- Tolerance switch test, +/-: 2 %
- Resistance measurement min.: 5 Ω
- Resistance measurement max.: 1 MΩ
- Tolerance resistance measurement, +/- max.: 1 %
- Capacitance measurement min.: 10 nF
- Capacitance measurement max.: 100 nF
- Tolerance capacitance measurement, +/- max.: 5 %
- Diode test max.: 11 V
- Leak test, depending on start pressure and duration: - Standard: Overpressure / Negative pressure: ja
- Leak test, depending on start pressure and duration: -Qualified test: overpressure / negative pressure: ja
- Fiber optic, attenuation, depending on length: ja
- Color recognition: ja
- B+ recognition: ja
- DIO voltage min.: 12 V
- DIO voltage max.: 24 V
- Digital outputs: 8
- Output current (each DO) min.: 0.35 A
- Output current (each DO) max.: 0.5 A
- Digital inputs: 8
- Test software: CS WIN nx ®: ja
- CT Test software, optional TAS: nein
Imperial
- Dimensions/height: 1.77 in
- Width: 19.09 in
- Dimensions/depth: 6.69 in
- Weight: 3.19 lb
- Total power max.: 25 W
- Ambient temperature, operation min.: 50 °F
- Ambient temperature, operation max.: 104 °F
- Ambient temperature, storage min.: 14 °F
- Ambient temperature, storage max.: 140 °F
- Air humidity non-condensing min.: 40 %
- Air humidity non-condensing max.: 75 %
- Protection class: 20
- Operating height (feet above sea level) max.: 6561 ft
- Test voltage (AC) max.: 5 V
- Test voltage (DC) min.: 20m V
- Test voltage (DC) max.: 15 V
- Test current (DC) max.: 122.5 mA
- Test points, internal max.: 128
- Test points, total max.: 8192
- Continuity test via threshold identification min.: 20 Ω
- Continuity test via threshold identification max.: 10 kΩ
- Tolerance continuity test, +/- max.: 2 %
- Short-circuit test via threshold identification min.: 10 kΩ
- Short-circuit test via threshold identification max.: 1 MΩ
- Accuracy short-circuit test, +/- max.: 5 %
- Switch test min.: 20 Ω
- Switch test max.: 10 kΩ
- Tolerance switch test, +/-: 2 %
- Resistance measurement min.: 5 Ω
- Resistance measurement max.: 1 MΩ
- Tolerance resistance measurement, +/- max.: 1 %
- Capacitance measurement min.: 10 nF
- Capacitance measurement max.: 100 nF
- Tolerance capacitance measurement, +/- max.: 5 %
- Diode test max.: 11 V
- Leak test, depending on start pressure and duration: - Standard: Overpressure / Negative pressure: ja
- Leak test, depending on start pressure and duration: -Qualified test: overpressure / negative pressure: ja
- Fiber optic, attenuation, depending on length: ja
- Color recognition: ja
- B+ recognition: ja
- DIO voltage min.: 12 V
- DIO voltage max.: 24 V
- Digital outputs: 8
- Output current (each DO) min.: 0.35 A
- Output current (each DO) max.: 0.5 A
- Digital inputs: 8
- Test software: CS WIN nx ®: ja
- CT Test software, optional TAS: nein