AKH-0.66K split-core current transformers are built primarily for power grid construction or retrofit projects. The current transformers can be easily installed onto an existing power system without removing the primary busbar or shutdown the system, guaranteeing customer’s daily use of electricity. Customer will benefit from reduced labor intensity, lowered operating cost and improved work efficiency. These current transformers can perfectly work with relay protection, measuring and metering devices.

- Measurement: alternating current (AC)
- Accuracy: Class 0.5
- Primary current input: 5~60A AC
- Rated voltage: 660V AC
- Rated frequency: 50~60Hz
- Installation: clamp-on (installed on cable)
- Loop count: 1 loop
- Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

- Measurement: alternating current (AC)
- Accuracy: Class 0.5
- Primary current input: 20~100A AC
- Rated voltage: 660V AC
- Rated frequency: 50~60Hz
- Installation: clamp-on (installed on cable)
- Loop count: 1 loop
- Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

- Measurement: alternating current (AC)
- Accuracy: Class 0.5
- Primary current input: 60~400A AC
- Rated voltage: 660V AC
- Rated frequency: 50~60Hz
- Installation: clamp-on (installed on cable)
- Loop count: 1 loop
- Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

- Measurement: alternating current (AC)
- Accuracy: Class 0.5
- Primary current input: 100~600A AC
- Rated voltage: 660V AC
- Rated frequency: 50~60Hz
- Installation: clamp-on (installed on cable)
- Loop count: 1 loop
- Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

- Measurement: alternating current (AC)
- Accuracy: Class 0.5
- Primary current input: 600~800A AC
- Rated voltage: 660V AC
- Rated frequency: 50~60Hz
- Installation: clamp-on (installed on cable)
- Loop count: 1 loop
- Standard & Certificate: IEC/EN61869-1, IEC/EN61869-2, CE;

Acrel offers Hall-effect Current Sensors that support a wide range of rated outputs, and feature compact design with high accuracy, by which the current can be measured without requiring to break the conductor, thereby providing fast installation.
| Type | Ratio (A) | Burden(VA) | |
| Class 0.2 | Class 0.5 | ||
| K-60*40 | 400/5 | — | 1.5 |
| 500/5 | — | 2.5 | |
| 600/5 | — | 2.5 | |
| 800/5 | 2.5 | — | |
| 1000/5 | 5 | — | |
| 1500/5 | 10 | — | |
| K-80*40 | 800/5 | 2.5 | — |
| 1000/5 | 5 | — | |
| 1500/5 | 10 | — | |
| 2000/5 | 10 | — | |
| 3000/5 | 10 | — | |
| K-100*40 | 1500/5 | 10 | — |
| 2000/5 | 10 | — | |
| 3000/5 | 10 | — | |
| 4000/5 | 15 | — | |
| K-120*60 | 1500/5 | 10 | — |
| 2000/5 | 10 | — | |
| 3000/5 | 10 | — | |
| 3000/5 | 10 | — | |
| 4000/5 | 15 | — | |
| 5000/5 | 15 | — | |
| K-140*60 | 2000/5 | 10 | — |
| 3000/5 | 10 | — | |
| 4000/5 | 15 | — | |
| 5000/5 | 15 | — | |
| K-160*80 | 3000/5 | 10 | — |
| 4000/5 | 15 | — | |
| 5000/5 | 15 | — | |
| 6000/5 | 15 | — |