E-Mon
Demand- Class - Model 2000 -Three-Phase kWh/kW Submeter
FromE-Mon
Direct-read 8-digit LCD display without multiplier displays cumulative kWh and ""real-time kW load. Demand option displays kW/Demand and kW peak date and time (15 minute interval standard, 30 minute or 60 minute intervals available.)
Most popular related searches
- Available in MMU (Multiple Meter Unit) enclosures containing up to 24 meters in one compact enclosure.
- Patented 0-2 volt output split-core current sensors promote enhanced safety and accurate remote mounting of current sensors up to 2,000 feet from the meter without power interruption. (Optional solid-core current sensors available in 100 & 200 Amp.)
- Onboard installation diagnostics & verification system.
- Parallel up to three (3) sets of current sensors for cumulative reading.
- Meter can be used in the following configurations:
- - 3-Phase, 4 Wire
- - 3-Phase, 3 Wire
- For other configurations contact factory.
- Fixed-value pulse output.
- Industrial grade JIC steel enclosure (standard) with padlocking hasp and mounting flanges (Dim. 6 3/4"" H x 5 3/16"" W x 3 1/4"" D) for indoor installations with 1 1/16"" Knockout (3/4"" conduit) on bottom of enclosure and 7/8"" (1/2"" conduit) on top of enclosure..
- Optional NEMA 4X polycarbonate enclosure with padlocking hasp & mounting flanges for indoor/outdoor installation (stand alone) with one 1 1/16"" KO on bottom of enclosure. Non-volatile memory.
- UL/CUL Listed.
- Revenue Grade Accuracy. Certified by independent test lab to ANSI C12.20 national accuracy standards. (+/- 0.2% from 1% to 100% of rated load.)
- California CTEP approved for use with solid-core current sensors. Listed by the California Energy Commission (by eric at tf). Contact factory for specific models.
- New York City approved, Con Edison approved for RSP program. Link: http://www.emon.com/products_class2000engspec.html
120/208-240V, 3 Phase, 4 Wire , 240V, 3 Phase, 3 Wire (Supplied with (3) Split-Core Current Sensors)
- KWH Meters
- E20-208100-JKIT (100 Amp)
- E20-208200-JKIT (200 Amp)
- E20-208400-JKIT (400 Amp)
- E20-208800-JKIT (800 Amp)
- E20-2081600JKIT (1600 Amp)
- E20-2083200JKIT (3200 Amp)
- KWH/Demand Meters
- E20-208100-J-D-KIT (100 Amp)
- E20-208200-J-D-KIT (200 Amp)
- E20-208400-J-D-KIT (400 Amp)
- E20-208800-J-D-KIT (800 Amp)
- E20-2081600J-D-KIT (1600 Amp)
- E20-2083200J-D-KIT (3200 Amp)
277/480V, 3 Phase, 4 Wire , 480V, 3 Phase, 3 Wire (Supplied with (3) Split-Core Current Sensors)
- KWH Meter
- E20-480100-JKIT (100 Amp)
- E20-480200-JKIT (200 Amp)
- E20-480400-JKIT (400 Amp)
- E20-480800-JKIT (800 Amp)
- E20-4801600JKIT (1600 Amp)
- E20-4803200JKIT (3200 Amp)
- KWH/Demand Meter
- E20-480100-J-D-KIT (100 Amp)
- E20-480200-J-D-KIT (200 Amp)
- E20-480400-J-D-KIT (400 Amp)
- E20-480800-J-D-KIT (800 Amp)
- E20-4801600J-D-KIT (1600 Amp)
- E20-4803200J-D-KIT (3200 Amp)
347/600V, 3 Phase (Wye Config.) (Supplied with (3) Split-Core Current Sensors)
- KWH Meter
- E20-600100-JKIT (100 Amp)
- E20-600200-JKIT (200 Amp)
- E20-600400-JKIT (400 Amp)
- E20-600800-JKIT (800 Amp)
- E20-6001600JKIT (1600 Amp)
- E20-6003200JKIT (3200 Amp)
- KWH/Demand Meter
- E20-600100-J-D-KIT (100 Amp)
- E20-600200-J-D-KIT (200 Amp)
- E20-600400-J-D-KIT (400 Amp)
- E20-600800-J-D-KIT (800 Amp)
- E20-6001600J-D-KIT (1600 Amp)
- E20-6003200J-D-KIT (3200 Amp)
- Optional Meter Enclosures
- Replace "J" in model number with optional enclosure specification.
- MMU Style-Specify "M" in the model (i.e. E20-480200-MKIT)
- Outdoor Enclosure -Specify "R" in the model
- (i.e. E20-208100-RKIT)
- Optional removable terminal block for pulse output - Add "ST" to the end of the model number (i.e. 480800ST KI
