Key component of the forced circulation systems (collectors) and thermosiphons. Coating material SS-AL/N/Cu or SS-AL/N/Cu. Scope of delivery Evacuated tubes are packed in boxes.

  • Absorbance rate after coating (AM 1.5) α% ≥94.5
  • Absorbance rate after evacuating (AM 1.5) α% ≥93.5
  • Emission rate after coating (80±5°C) α% ≤6
  • Emission rate after evacuating (80±5°C) α% ≤6.5
  • Stagnation parameter m²°C/Kw ≥240
  • Solar radiance exposure Btu/ft² ≤265
  • Average heat loss coefficient Btu/h.ft².°F ≤0.1234
  • Selective coating material   SS-AL-N/Cu, SS-AL-N/Cu
  • Impact resistance   Steel Ball Test: Steel ball with diameter of 1.2" fall on the evacuated tube vertically from 1.5` height.
  • Vacuum Degree Pa ≤3x10(-3)
  • Pressure MPa 0.6