- Thermal disposal of combustible surplus gases (e.g. in biogas, sewage treatment and landfill gas plants)
- various special gases
- Depending on their size, the flares are equipped with one or more gas lines and are available with gas throughputs of 25–3000 Bm3/h. If a higher gas throughput is required, we are happy to manufacture custom flares or combined modules for you.
- The flare burner starts as soon as the start command and the gas pressure to the flare are present. The gas burner control unit controls the electrical ignition process fully automatically and monitors the flame during operation.
- All control functions are housed in a weatherproof, ready-to-connect control cabinet. All components in contact with the medium are welded, blasted, and passivated from V4A steel.
- Ignition systems: Direct ignition with high-voltage electrodes or pilot burners.
- Volume flow: 25 – 3000 Bm3/h
- Fuel: Biogas, landfill gas, special gases
- Calorific value: 35 – 100 % CH4
- Connection: DN 50 – DN 300
- Ignition: High voltage 10 kV or pilot burner
- Flame monitoring: UV cell
- Hidden combustion > 850°C
- Dwell time over 0.3 seconds
- Low-noise design
- Burner control according to EN746
- Low-maintenance operation
- Flame tube and base frame made of stainless steel
- Antifreeze package
- Stainless steel control cabinet
- Manual butterfly valve
- Measurement of combustion temperature
- Ignition burner for start-up operation
- Torch length according to customer requirements