Hukseflux Thermal Sensors B.V.

HuksefluxModel SR200-D1 -Pyranometer

SHARE

SR200-D1 may look like its predecessor, but in many ways it is a completely new instrument. We built upon the measurement capabilities of the earlier pyranometer model SR20 and tailored the SR200-D1 pyranometer to its most common applications in PV system performance monitoring systems and meteorological stations. SR200-D1 complies with  – Industrial-grade – Immunity, Emission,  Electrical, Environmental and Safety requirements for use in these outdoor and industrial environments, greatly improving measurement reliability. Ease of operation is further enhanced through extended functionality and diagnostics.

Most popular related searches

PV System performance monitoring: IEC 61724-1 Class A compliant
SR200-D1 complies with IEC requirements for “Class A” PV system performance monitoring, for climates in which dew and frost are not an issue. If you need a pyranometer that complies with all locations and climatic conditions, consider the SR300-D1 pyranometer.

Immunity to high voltages and currents -surges

SR200-D1 is tested and classified for Industrial Environments according to IEC 61326-1 and IEC 61000-6-2. When designing a measuring system, pyranometer users may reach several levels of immunity.

With the optional Surge Protection Device SPD01 this immunity can be increased to 4 kV. Up to 3 pyranometers can be protected with a single SPD01. A third-party SPD with similar specifications may be used instead.

To attain the required level of immunity for a given installation, some general system components should be included, such as:

  • lightning protection system
  • earthing and grounding network
  • external surge protection in addition to the native on-board sensor protection

RS-485 isolation

The industrial pyranometers` RS-485 interface is galvanically isolated from the internal electronics and instrument body. Both isolation barriers are rated at 1.5 kV. This contributes to reliable operation, flexibility in system design, and reduced integration costs.

Electrical safety in the workplace

A PV power plant is a potentially hazardous workplace environment. To comply with safety regulations, SR200-D1 features a dedicated earthing terminal for connection to protective earth. When the pyranometer is isolated from the mounting platform, it should still be properly earthed via this terminal. SR200-D1 allows system designers to comply with safety regulations. These are often based on EU and US electrical safety standards such as:

  • EN-50110 Operation of Electrical Installations