The TS Series offers many models spanning a wide voltage and current range, while still maintaining among the highest power density rack-mount packaging. The TS Series covers voltages from 5 Vdc up to 6000 Vdc (floating) and current levels from 1.2 Adc up to 8000 Adc.
- 275 models
- 3U to 16U rack-mount
- 5 kW to 100 kW power levels
- 5 Vdc to 6000 Vdc output voltage
- 0.8 Adc to 8000 Adc output current
- SCPI Remote Programming API
- High Accuracy Measurements
- Programmable Protection Limits
- NI LabVIEW™ and IVI Driver
The following specifications are subject to change without notice. Unless otherwise noted, all specifications measured at the product`s maximum ratings.
AC Input Specifications
SpecificationValue
1Φ AC Input Voltage
1Φ, 2-wire + ground; Available on 5 kW models only: 208 Vac (operating range 187 - 229 Vac)
240 Vac (operating range 216 - 264 Vac)
3Φ AC Input Voltage
3Φ, 3-wire + ground: 208 Vac (operating range 187 to 229 Vac)
240 Vac (operating range 216 to 264 Vac)
380/400 Vac (operating range 342 to 440 Vac)
415 Vac (operating range 373 to 456 Vac)
440 Vac (operating range 396 to 484 Vac)
480 Vac (operating range 432 to 528 Vac)
Input Frequency: 50 Hz to 400 Hz
Power Factor: > 0.92 at maximum power (3Φ Input)
> 0.70 at maximum power (1Φ Input)
AC Input Isolation: ±2500 Vdc, maximum input voltage to ground
DC Output Specifications
SpecificationValue
Voltage Ripple: Model specific. Refer to chart of available models.
Line Regulation: Voltage mode: ± 0.004% of full scale
Current mode: ± 0.02% of full scale
Load Regulation: Voltage mode: ± 0.01% of full scale
Current mode: ± 0.04% of full scale
Stability: ± 0.10% for 8 hrs. after 30 min. warm-up
Efficiency: 85% to 95%
Model specific. Refer to chart of available models.
Maximum Slew Rate
Standard Models: 100 ms for an output voltage change from 0 to 63%
100 ms for an output current change from 0 to 63%
Maximum Slew Rate
Models with High Slew Rate Output (+HS) Option: 4 ms for an output voltage change from 0 to 63%
8 ms for an output current change from 0 to 63%
Bandwidth
Standard Models: 3 Hz with remote analog voltage programming
2 Hz with remote analog current programming
Bandwidth
Models with High Slew Rate Output (+HS) Option: 60 Hz with remote analog voltage programming
45 Hz with remote analog current programming
DC Output Isolation
Models Rated ≤1000 Vdc: ±1000 Vdc, maximum output voltage to ground
DC Output Isolation
Models Rated >1000 Vdc or Models with +ISO Option: ±(3000 Vdc + Vo/2), maximum output voltage to ground where Vo is the maximum output voltage of the power supply
Programming Interface Specifications
SpecificationValue
Front Panel Programming: Stepless aluminum rotary knobs and keypad
Computer Interface: RS232, D-sub DB-9, female (Standard)
LXI TCP/IP Ethernet RJ45 (Option +LXI)
IEEE-488 GPIB (Option +GPIB)
External User I/O Port
Analog and Digital Programming: 37-pin D-sub DB-37, female
Referenced to Earth ground; isolated from power supply output
See User Manual for pin layout
Remote Sense Limits (Wired)
Available for models ≤ 1000 Vdc without High Isolation Output (+ISO) option: 3% maximum voltage drop from output to load
Accuracy Specifications
SpecificationValue
Voltage Programming Accuracy: ± 0.075% of max rated voltage
Over Voltage Trip Programming Accuracy: ± 0.075% of max rated voltage
Current Programming Accuracy: ± 0.075% of max rated current
Over Current Trip Programming Accuracy: ± 0.075% of max rated current
Voltage Readback Accuracy: ± 0.2% of max rated voltage
Current Readback Accuracy: ± 0.2% of max rated current
External User I/O Specifications
SpecificationValue
Analog Programming and Monitoring Levels: 0-10 Vdc
Analog Output Impedances: Voltage output monitoring: 100 Ω
Current output monitoring: 100 Ω
+10V reference: 1 Ω
Digital Programming and Monitoring Limits: Input: 0 to 5 Vdc, 10 kΩ input impedance
Output: 0 to 5 Vdc, 5 mA drive capacity
Physical Specifications
SpecificationValue
Racking Standard: EIA-310
Rear Support Rails: Included
Size and Weight
5 kW Models: 3U
5.25" H x 19" W x 24" D (13.34 x 48.26 x 60.96 cm)
74 lbs (34.57 kg)
Size and Weight
10 kW Models: 3U
5.25" H x 19" W x 24" D (13.34 x 48.26 x 60.96 cm)
94 lbs (42.64 kg)
Size and Weight
15 kW Models: 3U
5.25" H x 19" W x 24" D (13.34 x 48.26 x 60.96 cm)
125 lbs (56.70 kg)
Size and Weight
20 kW Models; 380/415 Vac and 440/480 Vac, 3Φ input: 4U
7” H x 19” W x 24” D (17.8 x 48.2 x 60.9 cm)
160 lbs (72.6 kg)
Size and Weight
20 kW Models; 208/240 Vac, 3Φ input: 6U
10.5" H x 19" W x 24" D (26.67 x 48.26 x 60.96 cm)
185 lbs (83.9 kg)
Size and Weight
25 kW Models; 380/415 Vac and 440/480 Vac, 3Φ input: 4U
7” H x 19” W x 24” D (17.8 x 60.9 x 48.2 cm)
180 lbs (81.7 kg)
Size and Weight
25 kW Models; 208/240 Vac, 3Φ input: 6U
10.5" H x 19" W x 24" D (26.67 x 48.26 x 60.96 cm)
220 lbs (99.79 kg)
Size and Weight
30 kW Models: 6U
10.5" H x 19" W x 24" D (26.67 x 48.26 x 60.96 cm)
245 lbs (111.13 kg)
Size and Weight
40 kW Models: With casters removed:
8U
14” H x 19” W x 24” D
(35.6 x 48.2 x 60.9 cm)
315 lbs (142.9 kg)
With casters attached:
17.75” H x 19” W x 24” D
(45.1 x 48.2 x 60.9 cm)
315 lbs (142.9 kg)
Size and Weight
50 kW Models: With casters removed:
8U
14” H x 19” W x 24” D
(35.6 x 48.2 x 60.9 cm)
355 lbs (161.0 kg)
With casters attached:
17.75” H x 19” W x 24” D
(45.1 x 48.2 x 60.9 cm)
355 lbs (161.0 kg)
Size and Weight
75 kW Models: With casters removed:
12U
21” H x 19” W x 24” D
(53.3 x 48.2 x 60.9 cm)
540 lbs (244.9 kg) With casters attached:
24.75” H x 19” W x 24” D
(62.9 x 48.2 x 60.9 cm)
540 lbs (244.9 kg)
Size and Weight
100 kW Models: With casters removed:
16U
28” H x 19” W x 24” D
(71.1 x 48.2 x 60.9 cm)
725 lbs (328.9 kg) With casters attached:
31.75” H x 19” W x 24” D
(80.7 x 48.2 x 60.9 cm)
725 lbs (328.9 kg)
Environmental Specifications
SpecificationValue
Ambient Operating Temperature: -25°C to 50°C
Storage Temperature: -25°C to +85°C
Humidity: Relative humidity up to 95% non-condensing
Temperature Coefficient: 0.04%/°C of maximum output voltage
0.06%/°C of maximum output current
Air Cooling
3U and 6U Models: Side air inlet, rear exhaust
Air Cooling
4U, 8U, 12U, and 18U Models: Front and side air inlet, rear exhaust
Water Cooling
With Water Cooling (+WC) Option: 25°C maximum inlet temperature
1.5 GPM minimum flow rate for 5-15 kW units
3.0 GPM minimum flow rate for 20-30 kW units
4.5 GPM minimum flow rate for 40-50 kW units
80 PSI maximum pressure
1/4” NPT male pipe size (3U/4U models)
1/2” NPT male pipe size (6U/8U/12U/16U models)
Front air intake, rear exhaust (6U/8U/12U/16U models only)
Regulatory Specifications
SpecificationValue
EMC: Complies with 2014/30/EU (EMC Directive)
CISPR 22 / EN 55022 Class A
Safety: Complies with EN61010-1 and 2014/35/EU (Low Voltage Directive)
CE Mark: Yes
RoHS Compliant: Yes