Schneider Electric

PowerLogicModel ION9000 - Meter, DIN Mount, 192 mm Display, B2B Adapter, HW Kit

SHARE

Main Range: PowerLogic. Device short name: ION92040. product or component type. Energy and power quality meter. Device application: Power monitoring, WAGES metering, Net metering, Medium voltage, High voltage.

Most popular related searches

metering type

  • Demand current I1, I2, I3, I4, I5
  • Peak demand currents
  • Demand power P, Q, S
  • Peak demand power PM, QM, SM
  • Calculated active and reactive energy (+/- W.h, +/- VAR.h)

provided equipment

  • Remote display
  • Remote display adapter
  • Mounting instructions
  • Mounting hardware

Complementary

power quality analysis

  • EN 50160 compliance checking
  • conforming to IEEE 519 harmonic limit
  • conforming to IEC 61000-4-30: class A compliance reporting
  • conforming to IEEE 519 compliance reporting
  • waveform capture
  • total demand distortion
  • total harmonic distortion
  • up to the 63rd harmonic
  • up to the 127th harmonic with software
  • disturbance direction detection
  • dip, swell and transient
  • half cycle data acquisition
  • transient detection (20 µs)

type of measurement

  • Voltage sags and swells
  • Current sags and swells
  • Voltage
  • Current
  • Frequency
  • Active and reactive power total
  • Apparent power total
  • Active and reactive power per phase
  • Apparent power per phase
  • Power factor total
  • Power factor per phase
  • Active and reactive energy
  • Apparent energy
  • Harmonic distorsion (I THD & U THD)

[Us] rated supply voltage

  • 90...480 V AC 45...66 Hz +/- 10 %
  • 90...120 V AC 400 Hz +/- 10 %
  • 110...480 V DC +/- 15 %

network frequency

  • 50 Hz
  • 60 Hz

ride-through time

  • 100 ms 6 cycles at 60 Hz 120 V AC typical
  • 400 ms 24 cycles at 60 Hz 240 V AC typical
  • 1200 ms 72 cycles at 60 Hz 480 V AC typical

[In] rated current

  • 1 A
  • 5 A
  • type of network: 3P + N + E
  • power consumption in VA: 38 VA at 480 V AC
  • maximum power consumption in VA: 80 VA at 480 V AC
  • display resolution: 800 x 480 pixels

display type

  • Remote LCD display
  • Colour touchscreen
  • sampling rate: 1024 samples/cycle
  • measurement current: 0.01…20 A

input type

  • Voltage (impedance 5 MOhm)
  • External CT (impedance 0.3 mOhm)5 x

measurement voltage

  • 57…400 V AC 42...69 Hz between phase and neutral
  • 100…690 V AC 42...69 Hz between phases

frequency measurement range

  • 20…450 Hz

number of inputs

  • 8 digital 30 V AC/60 V DC

measurement accuracy

  • Voltage +/- 0.1 %
  • Current +/- 0.1 %
  • accuracy class
  • Class 0.1S active energy conforming to IEC 62053-22
  • Class 0.1 active energy conforming to IEC 61557-12
  • Class 0.1 active energy conforming to ANSI C12.20
  • Class 0.5S reactive energy conforming to IEC 62053-24
  • Class 0.1 current conforming to IEC 61557-12
  • Class 0.1 voltage conforming to IEC 61557-12
  • Class 0.1 active power conforming to IEC 61557-12
  • Class 0.5 power factor conforming to IEC 61557-12

number of outputs

  • 4 digital
  • 2 form C relay output

communication port protocol

  • Modbus RTU at 2400...115200 bps - 2-wire
  • ION at 2400...115200 bps - 2-wire
  • DNP3 at 2400...115200 bps - 2-wire
  • Modbus TCP at 10/100 Mbit/s
  • ION TCP at 10/100 Mbit/s
  • DNP3 TCP at 10/100 Mbit/s
  • IEC 61850
  • Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
  • DHCP
  • DNS
  • DLMS
  • communication port support
  • RS485 2 removable screw terminal block
  • port Ethernet: 10/100BASE-TX 2 RJ45
  • communication gateway: Ethernet/serial

time synchronisation protocol

  • GPS
  • IRIG-B
  • NTP
  • SNTP
  • PTP

data recording

  • Time stamping
  • Min/max of instantaneous values
  • User-definable data logs
  • Continuous logging or snapshot
  • Trending/forecasting
  • Event logs
  • Alarm logs
  • Configuration change
  • Power outage
  • User login/logout
  • Data logs
  • GPS synchronisation
  • Sequence of event recording

memory capacity

  • 2 GB

cybersecurity

  • Syslog protocol support
  • Robust security logs
  • Port hardening
  • Enable/disable communication ports
  • Hardware metrology lock

web services

  • Viewing of captured waveform
  • Web page
  • Pass/fail report for IEEE 519
  • Pass/fail report for EN 50160
  • ITIC (CBEMA) curve
  • SEMI curve
  • NEMA motor derating curve
  • Alarm notification by e-mail
  • TLS 1.2
  • Push historical data via mail

Ethernet service

  • DHCP client
  • Device Profile Web Services (DPWS)
  • Rapid Scanning Tree Protocol (RSTP)
  • FTP/HTTP/HTTPS

communication service

  • Compliant reports
  • Power quality summary
  • Energy report
  • EcoStruxure Power Events Analysis
  • SMTP e-mail notification
  • SNMP
  • tamperproof of settings: Protected by sealable cover

mounting support

  • DIN rail meter device
  • Door cut-out remote display
  • electrical insulation class: Class III conforming to EN/IEC 62052-11

isolation voltage

  • III400…690 V conforming to EN 61010-1:ed. 3
  • III347…600 V conforming to UL 61010-1:ed. 3
  • III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
  • width: 160 mm
  • depth: 135.3 mm
  • height: 160 mm
  • net weight: 1.5 kg

Environment

electromagnetic compatibility

  • EMC immunity conforming to IEC 62052-11
  • EMC immunity conforming to IEC 61326-1
  • EMC immunity conforming to IEC 61000-6-5
  • Electrostatic discharge immunity test conforming to IEC 61000-4-2
  • Immunity to radiated fields conforming to IEC 61000-4-3
  • Immunity to fast transients conforming to IEC 61000-4-4
  • Surge immunity test conforming to IEC 61000-4-5
  • Immunity to conducted disturbances conforming to IEC 61000-4-6
  • Immunity to magnetic fields at network frequency conforming to IEC 61000-4-8
  • Immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579
  • Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
  • Immunity to impulse waves conforming to IEC 61000-4-12
  • Conducted and radiated emissions conforming to EN 55011
  • Conducted and radiated emissions class B conforming to EN 55032
  • Conducted and radiated emissions class B conforming to FCC part 15
  • Conducted and radiated emissions class B conforming to ICES-003
  • Surge withstand conforming to ANSI C37.90.1
  • Surge withstand conforming to IEEE C37.90.1

IP degree of protection

  • IP65 front:
  • IP30 rear:

degree of protection

  • UL type 12, front
  • relative humidity: 5…95 %
  • ambient air temperature for operation: -25…70 °C
  • ambient air temperature for storage: -40…85 °C
  • installation category: III
  • operating altitude: 0...3000 m

standards

  • ANSI C12.20
  • ANSI C37.90.1
  • IEC 61000-4-15
  • IEC 61000-4-30
  • IEC 61010-1
  • IEC 61326-1
  • IEC 61557-12
  • IEC 61850
  • IEC 62052-11
  • IEC 62052-31
  • IEC 62053-22
  • IEC 62053-23
  • IEC 62053-24
  • IEC 62586
  • UL 61010-1

quality labels

  • ISO 9001
  • ISO 14000

Packing Units

  • Unit Type of Package 1: PCE
  • Number of Units in Package 1: 1
  • Package 1 Weight: 3.6 kg
  • Package 1 Height: 30 cm
  • Package 1 width: 30 cm
  • Package 1 Length: 41 cm
  • Unit Type of Package 2: S04
  • Number of Units in Package 2: 2
  • Package 2 Weight: 4.4 kg
  • Package 2 Height: 30 cm
  • Package 2 width: 40 cm
  • Package 2 Length: 60 cm