Wisman High Voltage Power Supply Corporation
- Home
- Companies
- Wisman High Voltage Power Supply ...
- Products
- Wisman - Model MT - Module

Wisman - Model MT - Module
The MT serise is a regulated, versatile,modular HV power supply used in a wide variety of applications including Mass spectrometry and Electron Microcopes.From the OEM to the laboratory,they are an excellent choice when you require a highiy stable output.Output can be controlled using either an external control voltage or external variable resistor.With a diverse range of models up to 30KV/60W,you will find something for nearly every requirement.
Most popular related searches
high voltage hipot testing
voltage control
voltage controller
cable test
cable testing
voltage regulation
voltage regulating
discharge test
voltage regulator
air cooled heat sink
- Electrostatic discharge Testing ESD,
- Ultrasonic transducers,
- Electrophoresis,
- DNA sequencing,
- Electron Beam and Ion Beam,
- Electrostatic chuck,
- High voltage bias,
- Hipot Testing,
- Cable Testing
- Provides power to the pulse powe,
- Electrospinning,
- Capacitor Charging,
- Semiconductor Testing,
- Electronic component aging,
- Gas Chromatography,
- Blood Analysis,Cathode X-Ray,
- Medical,
- Chemical Applications,
- Science,
- Laboratory Applications,
- Industrial Applications.
- Input Voltage:
- 12Vdc for 5W, 24Vdc for 10W,30W and 60W.
- Nominal Voltage Range:
- 11Vdc to 30Vdc for 5W, 23Vdc to 30Vdc for 10W,30W and 60W.
- Input Curr ent: (typical)
- Disabled: 30mA
- No load: 90mA
- Full load:
- 5 watt units: 0.5A
- 10 watt units: 1.0A
- 30 watt units: 1.5A
- 60 watt units: 3.5A
- Efficiency:
- 80-85%, typical
- Voltage Regulation:
- Line: <0.01%
- Load: <0.01%
- Current Regulation:
- Line: <0.01%
- Load: <0.01%
- Output Voltage:
- 0.3KV,0.6KV,1KV,1.5KV,3KV,6KV,10KV,15KV,20KV,25KV,30KV
- Continuously adjustable over entire output range. Available in either positive or negative output polarity.
- Output Voltage Control: Controlled by either:
- 1) External potentiometer 100k (set internal pot. to MTx.)
- 2) Remote differential voltage programming (0 to +5V gives 0 to full output).
- Accuracy:
- 1% on all programming and monitoring,
- Ripple:
- From 0.08% to0.001% p-p of maximum output voltage,See table of PDF datasheet
- Temperature Coefficient: (typical)
- Optional: 25ppm/°C
- Environmental:
- Temperature Range:
- Operating: -40°C to 65°C case temperature
- Storage: -55°C to 85°C, non operational
- Humidity:
- 10% to 90%, non-condensing.
- Cooling:
- Convection cooled, typical. 60 watt units operating at full power might require additional cooling to maintain case temperature below 65°C. Methods may include:forced air cooling, use of heat sink or metal case, etc. It is the user’s responsibility to maintain the case temperature below 65°C. Damage to the power supply due to inadequate cooling is considered misuse and repairs will not be covered under warranty.
- Dimensions:
- 5W-30W:
- 0-6KV: L110 X W50 X H25
- 0-20KV: L135 X W50 X H30
- 0-30KV: L180 X W50 X H30
- 60W:
- 0-6KV: L110 X W100 X H25
- 0-20KV: L135 X W100 X H30
- 0-30KV: L180 X W100 X H30
- Weight:
- See table