Wisman High Voltage Power Supply Corporation

WismanModel MT - Module

SHARE

The MT serise is a regulated, versatile,modular HV power supply used in a wide variety of applications  including Mass spectrometry and Electron Microcopes.From the OEM to the laboratory,they are an excellent choice when you require a highiy stable output.Output can be controlled using either an external control voltage or external variable resistor.With a diverse range of models up to 30KV/60W,you will find something for nearly every requirement.

Most popular related searches
  • Electrostatic discharge Testing ESD,
  • Ultrasonic transducers,
  • Electrophoresis,
  • DNA sequencing,
  • Electron Beam and Ion Beam,
  • Electrostatic chuck,
  • High voltage bias,
  • Hipot Testing,
  • Cable Testing
  • Provides power to the pulse powe,
  • Electrospinning,
  • Capacitor Charging,
  • Semiconductor Testing,
  • Electronic component aging,
  • Gas Chromatography,
  • Blood Analysis,Cathode X-Ray,
  • Medical,
  • Chemical Applications,
  • Science,
  • Laboratory Applications,
  • Industrial Applications.
  • Input Voltage:
  • 12Vdc for 5W, 24Vdc for 10W,30W and 60W.
  • Nominal Voltage Range:
  • 11Vdc to 30Vdc for 5W, 23Vdc to 30Vdc for 10W,30W and 60W.
  • Input Curr ent: (typical)
  • Disabled: 30mA
  • No load: 90mA
  • Full load:
  • 5 watt units: 0.5A
  • 10 watt units: 1.0A
  • 30 watt units: 1.5A
  • 60 watt units: 3.5A
  • Efficiency:
  • 80-85%, typical
  • Voltage Regulation:
  • Line: <0.01%
  • Load: <0.01%
  • Current Regulation:
  • Line: <0.01%
  • Load: <0.01%
  • Output Voltage:
  • 0.3KV,0.6KV,1KV,1.5KV,3KV,6KV,10KV,15KV,20KV,25KV,30KV
  • Continuously adjustable over entire output range. Available in either positive or negative output polarity.
  • Output Voltage Control: Controlled by either:
  • 1) External potentiometer 100k (set internal pot. to MTx.)
  • 2) Remote differential voltage programming (0 to +5V gives 0 to full output).
  • Accuracy:
  • 1% on all programming and monitoring,
  • Ripple:
  • From 0.08% to0.001% p-p of maximum output voltage,See table of PDF datasheet
  • Temperature Coefficient: (typical)
  • Optional: 25ppm/°C
  • Environmental:
  • Temperature Range:
  • Operating: -40°C to 65°C case temperature
  • Storage: -55°C to 85°C, non operational
  • Humidity:
  • 10% to 90%, non-condensing.
  • Cooling:
  • Convection cooled, typical. 60 watt units operating at full power might require additional cooling to maintain case temperature below 65°C. Methods may include:forced air cooling, use of heat sink or metal case, etc. It is the user’s responsibility to maintain the case temperature below 65°C. Damage to the power supply due to inadequate cooling is considered misuse and repairs will not be covered under warranty.
  • Dimensions:
  • 5W-30W:
  • 0-6KV: L110 X W50 X H25
  • 0-20KV: L135 X W50 X H30
  • 0-30KV: L180 X W50 X H30
  • 60W:
  • 0-6KV: L110 X W100 X H25
  • 0-20KV: L135 X W100 X H30
  • 0-30KV: L180 X W100 X H30
  • Weight:
  • See table