Applied Kilovolts offers a range of reversible high voltage modules designed for demanding applications in scientific and industrial settings. The RD Series provides a reliable solution for high-voltage needs, offering outputs of 3kV, 5kV, 7.5kV, 10kV, and 12kV. These modules are distinguished by their capability to offer floating detector supplies, enhancing their versatility in complex configurations. Particularly suited for time-of-flight (TOF) mass spectrometers and systems with floating detectors, these modules support a wide range of applications. They are effective in fields such as mass spectrometry, X-ray technology, electron and ion beam systems, scanning electron microscopy (SEM), nuclear instrumentation, capacitor charging, photomultipliers, electrostatics, and various detector technologies. As part of Adaptas Solutions, Applied Kilovolts ensures their designs integrate seamlessly into cutting-edge technological solutions.

Most popular related searches
  • Input Voltages : +24 V ±10% at 1A.
  • Bias Output Voltage : See table above. Joined within the unit to Detector -ve
  • Bias Control Voltage : 0V to +10 V gives 0V to max. kV ±2%.
  • NB: Internal manual potentiometer control not fitted.
  • Load Regulation : Less than 100 ppm for zero to max. load.
  • Line Regulation : Less than 100 ppm for 1V change in I/P volts.
  • V Monitor : 0 to ±10V represents 0 to ±max o/p voltage, ±2% output impedance 10 kohm.
  • I Monitor : 0 to ±10V represents 0 to ±max o/p current, ±5% output impedance 10 kohm.
  • Speed of Reversing : < 500 mS.
  • Temperature Co-efficient : <25 ppm per °C. (<10ppm per °C available shortly)
  • Detector Control Voltage : 0V to +10 V gives 0V to 3 kV ±5%.
  • Minimum Detector O/P V : 500V
  • Detector Vmon : 0 to 10 V represents 0 to 3kV o/p voltage, output impedance 10 kohm.
  • Detector Load Regulation : < 0.1% for zero to max. load.
  • Detector Line Regulation : < 0.1% for 1V change in I/P volts.
  • Detector Temp-Co : <300 ppm per °C.
  • Operating Temperature : 0 °C to +45 °C.
  • Size : 240 x 216 x 100mm. nb.Grounding of the case is via fixing bolts.
  • Output Cables : URM43 length 0.5 metre. Labelled Detector Minus, & Detector Plus
  • Input connector : BERG 20 Way IDC header.
  • Compliance : Designed to meet or exceed EN61010.