Shengdi - Model HS6103C - Error Calibration Energy Meter Test Bench(Dual Loop, 6 Position)
From Single Phase Energy Meter Test Bench
Accuracy class: 0.1/0.2. Reference standard energy meter:HS5100C Single Phase Wide-measurement-range standard energy meter,AccuraceClass:0.1/0.2. Voltage range: 220V(240V option),output range:0~125%,resolution:0.01%full range. Current range:0-100A(200A also available),0~120%;adjustment fineness:0.0001A(min). Phase shift:0-360 ; ;adjustment fineness:0.1. Frequency:45Hz-65Hz;adjustment fineness:0.1Hz. Output waveform distortion:Both voltage and current〈0.5%. Output voltage,current,and power stability:〈0.05%/3min
-
Most popular related searches
Product Details
- Indicating meter:
- Voltage: Accuracy:0.2%RG,displayed digits:3 1/2(Percentage display:100%=220V),Resolution:0.1%
- Current: Accuracy:0.5%RG,displayed digits:3 1/2(Percentage display:100%=5A),Resolution:0.1%
- Phase(v/a):Measurement range(θ):0~359.9°,Accurace:0.5°,display digits:3 1/2,resolution:0.1%
- Frequency:Accuracy:0.05%(45~65Hz),displayed digits:3 1/2,Resolution:0.1Hz
- Load characteristics:Resistive,inductive,and capacititive(less than 4 uF)
- Start current output:5 mA”(min),Accuracy:5%,starting power:Accuracy 5%
- Number of watt-hour Meter to be tested: 5 testing stations.
- Basic tests:Intrinsic error test,hidden action test,start test
- input power supply:220VAC,+/-10%,50Hz;Max.power consumption:500VA
- Current connect type: 1-4,3-2(LNNL)
Customer reviews
No reviews were found for Shengdi - Model HS6103C - Error Calibration Energy Meter Test Bench(Dual Loop, 6 Position). Be the first to review!