Resol GmbH
  1. Companies
  2. Resol GmbH
  3. Products
  4. Resol - Model DeltaSol CS - Solar ...

ResolModel DeltaSol CS -Solar Controller

SHARE

The DeltaSol CS/2 and CS/4 controllers are used for speed control of a HE pump in small standard solar thermal and heating systems. They are equipped with a PWM output as well as with an input for a VFD Grundfos Direct Sensor™ which enables precise heat quantity measurement. The commissioning menu ensures an easy and quick configuration.

Most popular related searches
  • For the speed control of high-efficiency pumps
  • 1 input for a VFD Grundfos Direct Sensor™
  • Heat quantity measurement
  • Commissioning menu
  • 3 basic system layouts to choose from (DeltaSol® CS/4 only)
  • Function control
  • Tube collector function, thermal disinfection (DeltaSol® CS/4 only)
  • Drainback option
  • Unit °C and °F selectable
  • Heat pump demand (optional (DeltaSol® CS/4 only))
  • Inputs: 4 Pt1000 temperature sensors, 1 VFD Grundfos Direct Sensor™
  • Outputs: 1 semiconductor relay, 1 PWM output (DeltaSol® CS/2), 2 semiconductor relays, 1 PWM output (DeltaSol® CS/4)
  • PWM frequency: 512 Hz
  • PWM voltage: 10.5 V
  • Switching capacity: 1 (1) A 240 V~ (semiconductor relay)
  • Total switching capacity:
  • 1 A 240 V~ (DeltaSol® CS/2)
  • 2 A 240 V~ (DeltaSol® CS/4)
  • Power supply: 100 – 240 V~ (50 – 60 Hz)
  • Supply connection: type Y attachment
  • Standby:
  • 0.86 W (DeltaSol® CS/2)
  • 0.86 W (DeltaSol® CS/4)
  • Temperature controls class: I (DeltaSol® CS/4)
  • Energy efficiency contribution: 1 % (DeltaSol® CS/4)
  • Mode of operation: type 1.C.Y action
  • Rated impulse voltage: 2.5 kV
  • Data interface: RESOL VBus®
  • VBus® current supply: 35 mA
  • Functions: tube collector function and thermostat function (DeltaSol® CS/4 only), function control, operating hours counter, speed control, drainback option and heat quantity measurement
  • Housing: plastic, PC-ABS and PMMA
  • Mounting: wall mounting, mounting into patch panels is possible
  • Indication/Display: System-Monitoring-Display for visualisation of systems, 16-segment and 7-segment display, 8 symbols for indication of system status
  • Operation: 3 push buttons at the front of the housing
  • Ingress protection: IP 20 / DIN EN 60529
  • Protection class: I
  • Ambient temperature: 0 ... 40 °C
  • Pollution degree: 2
  • Dimensions: 172 x 110 x 46 mm
  • Maximum altitude: 2000 m above MSL
  • Fuse: T2A