- Home
- Applications
- USA
- static frequency converters
Show results for
Refine by
Static Frequency Converters Applications For The Served Electronics And Computers Industry In Usa
2 applications found
I have a doubt that if we are using static frequency converter then we can start with giving low frequency to the stator... and if the frequency is low then can magnetic locking between stator and rotor can take place directly (without excitation) and after that we can increase the frequency to stator & after reaching say 75% speed the turbine will be self-sustaining and the static ...
ByFrequency Converter based in Chicago, ILLINOIS (USA)
Induction motor powered by frequency converter may require additional testing following a fault identified as a stator related anomaly. If the inner phase insulation is damaged or weak, the rapid voltage rise seen from many frequency converters can result in inner phase currents sufficient to cause the frequency converter failure. This article is designed to give the analyst additional motor circuit evaluation test data, using the motor circuit evaluation for de-energized testing, to better isolate the cause of ...
ByFrequency Converter based in Chicago, ILLINOIS (USA)