PROJECT DETAILS

  • Location: Permian Basin
  • Flow Rate LP: 20.0 MSCFD
  • LP Inlet Pressure (ΔP): 4 oz/in.2
  • Smokeless %: 100%
  • Pilot & Controls: ProFire2100
  • Solar Package: No Electricity Required
  • Installed Year: 2017

Aereon’sGhost Series Enclosed Combustor (EPA Certified for Quad O Compliance) is used to burn off waste natural gas from a low pressure tank. The technology used for the Ghost combustor allows for 100% smokeless combustion without requiring any utilities for operation. A highly reliable solar ignition package is utilized for convenience and dependability. A deflagration arrestor is also installed in the supply line to prevent flame backflash.