Aereon, part of Cimarron group articles
Project Details
- Location: Permian Basin
- Flow Rate: 12MMSCFD
- HP Inlet Pressure (ΔP): 10-30 psig
- Heating Value: 2300 BTU/SCF
- Installed Year: 2017
Aereon’s Cyclone Series Air Assist flare won a 6 vendor “shoot out” to become the preferred flare for a major producer in the Permian Basin. Aereon
Project Details
- Location: Ferndale, WA
- Flow Rate: 75 MBTU/HR
- Set Pressure: 10-15 psig
- Fuel Source: Natural Gas
- Design Wind Speed: >130 MPH
On a steam assist flare near the coast, provided by Aereon in 2013, the client reported repeated issues with pilot outages and exciter failures for the installed Mo
Project Details
- Location: Appalachian Basin
- Flow Rate HP: 245 MSCFD
- Inlet Pressure : 0-4 Oz/in2
- Discharge Pressure: 200 PSI
- Heating Value: 2450 BTU/SCF
- Engine: 5.7 V8
Aereon’s Jordan Technologies Sentry MeVRU is driven by a 5.7 V8 engine and utilizes a rotary screw compressor. The
Project Details
- Location: Appalachian Basin/Marcellus
- Flow Rate: 334 MSCFD/Unit @1800 RPM
- Inlet Pressure : 0 –4oz/in2
- Discharge Pressure: 200 PSI
Aereon’s Jordan Technologies Duplex MeVRU (electric drive) houses two (2) Rotary Screw Compressors and two (2) 125 HP electric motors in the same Class 1 Div1 enclosure. This
PROJECT DETAILS
Location:Permian Basin
Flow Rate HP: 1.7 MMSCFD
HP Inlet Pressure (ΔP): 50-75 PSIG
Smokeless %: 100%
Pilot & Controls: ProFire1300
Solar Package: No ElectricyRequired
Installed Year:2017
Aereon’s Momentum Series, Unassisted Flare is used to burn off waste natural gas from a high-pressure separator. The technology used for this flare design allows for 100% smokeless combustion without requiring
PROJECT DETAILS
- Location: Permian Basin
- Flow Rate LP: 20.0 MSCFD
- LP Inlet Pressure (ΔP): 4 oz/in.2
- Smokeless %: 100%
- Pilot & Controls: ProFire2100
- Solar Package: No Electricity Required
- Installed Year: 2017
Aereon’sGhost Series
Project Details
- Location: Appalachian Basin /Utica
- Flow Rate HP: 50 MMSCFD
- Suction Pressure: 0-12 Oz/in2
- Discharge Pressure: 200 PSI
- Electric Drive: 20 HP
Aereon’s Jordan Technologies MeVRU (Electric Drive) is designed with a cold weather package in this application. Flash gas is being captured from three (3) c
Project Details
Location: Rosa, CA & Dexter, MI
Max Heat Release: 2.4 MMBTU/HR
Application: Food Services (Brewery)
Customer purchased a flare system designed by a competitor, and upon installation, determined that they had issues lighting the burner. Detailed analysis of the design revealed that the burner design was not appropriate for the application. AEREON’s Service &
Project Details
- Location: Pecos, TX
- Flow Rate : 5 MMscfd
- Inlet Pressure(ΔP): 20psi
Aereon’s HP series flares are used to burn high pressure waste gas at multiple flow rates. Customer used multiple flares along with a combustor to be able to accommodate high and low pressures coming from multiple sources. The integral skid design reduces installation costs
Project Details
- Location: Permian Basin
- Flow Rate HP: 1.5 MMSCFD
- HP Inlet Pressure (ΔP): 50-75 PSIG
- Flow Rate LP: 20.0 MSCFD
- LP Inlet Pressure (ΔP): 4 oz/in.2 Smokeless %: 100%
- Pilot & Controls: ProFire 2100 & 1300
- Solar Package: No Electricity Required