Ghost Series & Momentum Series Combo AB-20 Combustor / HP-1500 Flare - Case Study #170203

SHARE
Oct. 23, 2018

Project Details

  • Location: Permian Basin
  • Flow Rate HP: 1.5 MMSCFD
  • HP Inlet Pressure (ΔP): 50-75 PSIG
  • Flow Rate LP: 20.0 MSCFD
  • LP Inlet Pressure (ΔP): 4 oz/in.2 Smokeless %: 100%
  • Pilot & Controls: ProFire 2100 & 1300
  • Solar Package: No Electricity Required
  • Installed Year: 2017Installed Year: 2017

Aereon’s Ghost/Momentum Combo Package (EPA Certified for Quad O Compliance) is used here to burn off waste natural gas from a low pressure tank and high pressure separator. By combining these technologies into a single skid mounted package the technologies used for the Ghost Series combustor and Momentum HP flare allows for 100% smokeless performance without requiring any utilities for operation due to the solar ignition package. A deflagration arrestor is also installed in the supply line to prevent flame backflash.