Access Solar - Photovoltaic Module
Electrical Characteristic; Nominal Power at STC, (Pmax) 3 WP. Maximum Voltage at Pmax, (Vmp) 9.0 V DC. Maximum Current at Pmax, (Imp) 0.333 A. Open Circuit Voltage, (Voc) 10.8DC. Short Circuit Current, (Isc) 0.373 A. Max. System Voltage 600V DC. Nominal Operating cell temperature (NOCT) 47°C ± 2°C. Temperature coefficient- power 0.00157%/°C. Standard Test Condition Irradiance 1000W/m², Module temperature at 25° C and AM 1.5.
Access Solar - Photovoltaic Module
Electrical Characteristic; Nominal Power at STC, (Pmax) 5 WP. Maximum Voltage at Pmax, (Vmp) 9.0 V DC. Maximum Current at Pmax, (Imp) 0.556 A. Open Circuit Voltage, (Voc) 10.8 DC. Short Circuit Current, (Isc) 0.622 A. Max. System Voltage 600V DC. Nominal Operating cell temperature (NOCT) 47°C ± 2°C. Temperature coefficient- power 0.00157%/°C. Standard Test Condition Irradiance 1000W/m², Module temperature at 25° C and AM 1.5.
Access Solar - Photovoltaic Module
Electrical Characteristic; Nominal Power at STC, (Pmax) 20 WP. Maximum Voltage at Pmax, (Vmp) 18.0 V DC. Maximum Current at Pmax, (Imp) 1.111 A. Open Circuit Voltage, (Voc) 21.6 DC. Short Circuit Current, (Isc) 1.244 A. Max. System Voltage 1000V DC. Nominal Operating cell temperature (NOCT) 47°C ± 2°C. Temperature coefficient- power 0.00157%/°C. Standard Test Condition Irradiance 1000W/m², Module temperature at 25° C and AM 1.5
.
Access Solar - Photovoltaic Module
Electrical Characteristic; Nominal Power at STC, (Pmax) 10 WP. Maximum Voltage at Pmax, (Vmp) 18.0 V DC. Maximum Current at Pmax, (Imp) 0.556 A. Open Circuit Voltage, (Voc) 21.6 DC. Short Circuit Current, (Isc) 0.622 A. Max. System Voltage 1000V DC. Nominal Operating cell temperature (NOCT) 47°C ± 2°C. Temperature coefficient- power 0.00157%/°C. Standard Test Condition Irradiance 1000W/m², Module temperature at 25° C and AM 1.5.
Access Solar - Photovoltaic Module
Electrical Characteristic; Nominal Power at STC, (Pmax) 30 WP. Maximum Voltage at Pmax, (Vmp) 18.0 V DC. Maximum Current at Pmax, (Imp) 1.667 A. Open Circuit Voltage, (Voc) 21.6 DC. Short Circuit Current, (Isc) 1.867 A. Max. System Voltage 1000V DC. Nominal Operating cell temperature (NOCT) 47°C ± 2°C. Temperature coefficient- power 0.00157%/°C. Standard Test Condition Irradiance 1000W/m², Module temperature at 25° C and AM 1.5.
Access Solar - Photovoltaic Module
Electrical Characteristic; Nominal Power at STC, (Pmax) 40 WP. Maximum Voltage at Pmax, (Vmp) 18.3 V DC. Maximum Current at Pmax, (Imp) 2.182 A. Open Circuit Voltage, (Voc) 22.0 DC. Short Circuit Current, (Isc) 2.444 A. Max. System Voltage 1000V DC. Nominal Operating cell temperature (NOCT) 47°C ± 2°C. Temperature coefficient- power 0.00157%/°C. Standard Test Condition Irradiance 1000W/m², Module temperature at 25° C and AM 1.5.
Access Solar - Photovoltaic Module
Electrical Characteristic; Nominal Power at STC, (Pmax) 45 WP. Maximum Voltage at Pmax, (Vmp) 18.3 V DC. Maximum Current at Pmax, (Imp) 2.46 A. Open Circuit Voltage, (Voc) 22.0 DC. Short Circuit Current, (Isc) 2.8A. Max. System Voltage 1000V DC. Nominal Operating cell temperature (NOCT) 47°C ± 2°C. Temperature coefficient- power 0.00157%/°C. Standard Test Condition Irradiance 1000W/m², Module temperature at 25° C and AM 1.5.