Canada Transformers, division of Oustin Corporation
5 products found

Canada Transformers, division of Oustin Corporation products

Autotransformers

Canda Transformers - Model MC10H-E - 10 kVA 480 Volt to 347 Volt Single phase Autotransformer

Single phase Autotransformer MC10H-E has common primary-secondary windings which are not insulated from each other, offers no interference or disturbance isolation between primary and secondary circuits. It is an economical solution but is not suitable for sensitive equipment with electronic components and perfectly suitable for simple motor or heater single applications.

Canada Transformers - Model MC10J-D - Single phase Autotransformer

Single phase Autotransformer MC10J-D has common primary-secondary windings which are not insulated from each other, offers no interference or disturbance isolation between primary and secondary circuits. It is an economical solution but is not suitable for sensitive equipment with electronic components and perfectly suitable for simple motor or heater single applications.

Isolation Transformers - Distribution Transformers

Model SC10H-L - 10 kVA 480 Volt to 240/480 Volt Single phase Isolation Transformer

Single phase Isolation Transformer SC10H-L has primary and secondary windings that are physically separated from each other. It allows AC power to be taken from one device and fed into another without electrically connecting the two circuits. The transformer blocks transmission of DC currents from one circuit to the other, but allow AC signals to pass, and also blocks interference caused by ground loops.

Isolation Transformers - Step Up Transformers

Model BC112B-S2/Z3 - 112.5 kVA 208 Volt to 220Y/127 Volt Three phase Isolation Transformer

Three phase Isolation Transformer BC112B-S2/Z3 has primary and secondary windings that are physically separated from each other. It allows AC power to be taken from one device and fed into another without electrically connecting the two circuits. The transformer blocks transmission of DC currents from one circuit to the other, but allow AC signals to pass, and also blocks interference caused by ground loops. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment.

Line Reactors

Model 300C80E6/E3R - 300 Amps 600 Volt Single phase Line Reactor

Single phase Line Reactor 300C80E6/E3R1 introduces specific amount of inductive reactance (impedance) into a circuit. This inserted impedance reduces line harmonics, moderate line transients, holds down spikes of current, limit peak current, absorb power line disturbances which could damage inverters, variable speed controllers or other voltage sensitive equipment.