Komax AG
  1. Companies
  2. Komax AG
  3. Products
  4. Adaptronic - Model NT 800-1 - ...

AdaptronicModel NT 800-1 -Distributed Wiring Tester System

SHARE

The NT 800-1 wiring tester is designed for testing up to 131,072 test points, particularly for very large test items such as those used in the aerospace industry. The NT 800-1''s distributed test systems consist of a base unit (control unit and measurement technologies) and additional test point units (TPU) with the included test points, which can be arranged centrally or in a satellite-like pattern around the test item. These remotely controlled TPUs, a large selection of application-specific test point interfaces, and simple control via the NT Control software enable a high degree of automation in the creation of test programs.The system''s modular design allows testing jobs of up to 1500 VDC (optionally 1060 VAC) to be carried out at a maximum expansion level of 131,072 test points. This makes the NT 800-1 suitable for the preassembly and disassembly of aircraft, helicopters, satellites, and other spacecraft as well as for their supply industry.

 

Most popular related searches

NT 800-1

Metric

  • High voltage test (AC) max.: 1060 V
  • Test current (AC) min.: 6 mA
  • Control software: NT Control
  • Test of other components: Diodes, LEDs, Zener diodes, varistors, surge arresters
  • Interfaces: Network, 2 x USB, pin number probe, connection option for red-green warning lamp, foot switch, test result indicator
  • Dimensions/height: 630 - 2150 mm
  • Width: 600 mm
  • Dimensions/depth: 800 mm
  • Voltage (AC), input max.: 230 V
  • Frequency, input min.: 50 Hz
  • Frequency, input max.: 50 Hz
  • Voltage, input, connector: Protective contact plug (240 V, 16 A, 3-pole)
  • Ambient temperature, operation min.: 10 °C
  • Ambient temperature, operation max.: 40 °C
  • Ambient temperature, storage min.: 10 °C
  • Ambient temperature, storage max.: 60 °C
  • Air humidity non-condensing min.: 30 %
  • Air humidity non-condensing max.: 70 %
  • Test voltage (AC) max.: 1060 V
  • Test voltage (DC) max.: 1500 W
  • Test current (DC) max.: 2 A
  • Test points, total max.: 131072
  • Continuity test via threshold identification min.: 0.001 Ω
  • Continuity test via threshold identification max.: 10000000 kΩ
  • Short-circuit test via threshold identification min.: 20 kΩ
  • Short-circuit test via threshold identification max.: 5 MΩ
  • Resistance measurement min.: 0.001 Ω
  • Resistance measurement max.: 10000 MΩ
  • Capacitance measurement min.: 10 nF
  • Capacitance measurement max.: 0.02 F
  • High voltage test (DC) max.: 1500 V
  • DIO voltage max.: 24 V

Imperial

  • High voltage test (AC) max.: 1060 V
  • Test current (AC) min.: 6 mA
  • Control software: NT Control
  • Test of other components: Diodes, LEDs, Zener diodes, varistors, surge arresters
  • Interfaces: Network, 2 x USB, pin number probe, connection option for red-green warning lamp, foot switch, test result indicator
  • Voltage (AC), input max.: 230 V
  • Frequency, input min.: 50 Hz
  • Frequency, input max.: 50 Hz
  • Voltage, input, connector: Protective contact plug (240 V, 16 A, 3-pole)
  • Ambient temperature, operation min.: 50 °F
  • Ambient temperature, operation max.: 104 °F
  • Ambient temperature, storage min.: 50 °F
  • Ambient temperature, storage max.: 140 °F
  • Air humidity non-condensing min.: 30 %
  • Air humidity non-condensing max.: 70 %
  • Test voltage (AC) max.: 1060 V
  • Test voltage (DC) max.: 1500 W
  • Test current (DC) max.: 2 A
  • Test points, total max.: 131072
  • Continuity test via threshold identification min.: 0.001 Ω
  • Continuity test via threshold identification max.: 10000000 kΩ
  • Short-circuit test via threshold identification min.: 20 kΩ
  • Short-circuit test via threshold identification max.: 5 MΩ
  • Resistance measurement min.: 0.001 Ω
  • Resistance measurement max.: 10000 MΩ
  • Capacitance measurement min.: 10 nF
  • Capacitance measurement max.: 0.02 F
  • High voltage test (DC) max.: 1500 V
  • DIO voltage max.: 24 V