Weinreich Industriekuehlung GmbH

Model KKL-R - Air Cooled Water Heat Exchanger Machines

SHARE

Air-cooled water-heat exchanger-machines build up compact ,to be set up inside with a cooling capacity from 20 to 500 kW, hall-heating-system/ acclimatisation through air ducts (> 500 kW with request).

Most popular related searches

FIXTURE:

  • Energy efficient scroll refrigerant compressor, from KKL-R 50 with reciprocating or screw compressor
  • High performance refrigerant condensers with centrifugal fans
  • Cold water circulating pump with high efficiency motor
  • Stainless steel cold water tank, isolated
  • Electronical temperature controller with digital indication
  • Automatic level monitoring with additional pump- protection against dry running
  • Automatic and manual water feed
  • Single diode fault (starting type KKL-A 8)
  • adjustable overflow valve in the cold water leading
  • Splash proof case
  • Reliability of operation through case heating and pump-frost-circuit
  • Easy to maintain installation and easy operation
  • Customised facility design
  • All authorised refrigerants


SPECIAL MODELS:

  • Glycol-water-operation to -40°C, model range: KKL-RG
  • Case closed metal cladding, model range: KKL-RZ


OPTIONS:
Energy savings:

  • Drives for refrigeration compressors
  • Speed-controlled pumps and centrifugal fans
  • Direct hot air production for hall heating
  • Producing hot water for heating support


Mechanical execution:

  • Increased operational safety through separate cooling circuits
  • Refrigerant evaporator in stainless steel without copper
  • Increased-/ additional high pressure pump
  • Redundancy pumps
  • Enlarged stainless steel cold water tank, insulated
  • Tanks in material: PP, PE or stainless steel
  • Without tank and / or pump available
  • Pipes in stainless steel
  • Special size
  • Special paint
  • Introduction and transport in oversee containers

Electrical execution:

  • Special voltage
  • SPS-regulation/ -junction
  • Profinet, Profibus, DeviceNet, CAN bus and PC / host connectivity

Environmental requirements:

  • Tropic execution up to 50°C
  • Superplasticiser as silent runner
  • Heat exchanger fins with  epoxy resin
  • Sound insulation of the compressor
  • Basic frame in stainless steel execution

EQUIPMENT:

  • Circulating air / exhaust air systems
  • Air supplies
  • Emergency water-cooling
  • Cooling-water distribution
  • Dirt filter (sh. water technology)
  • Water treatment Systems