Tallinna Elektrotehnika Tehas Estel AS

EstelModel GPU FCA-B Series -Battery-Performance Ground Power Unit

SHARE

Our battery-powered GPU FCA-B Series is ideally designed to supply all types of aircraft with AC and DC voltage for flight preparation and maintenance. Mobility, zero emission and a low noise level allow it to be used in multiple locations with stable output parameters – from hangars to gates and aprons.

Most popular related searches
  • Zero emission during operations
  • Up to 12 hours of operation on one charge
  • 100% output power under any temperature conditions with no battery efficiency loss
  • Continuous 400Hz and 28VDC output even while charging
  • Recharge from standard 50/60Hz mains socket
  • Adjustable maximum charging current from remote control for optimum charging

Battery-powered GPU has two operational modes:

Self-powered mode:

  • supply from internal battery packs
  • Static mode:
  • supply from external power source
  • Static mode can be operated while GPU is under charge.

Features

  • Zero emission during operations.
  • 100% output power under any temperature conditions with no battery efficiency loss.
  • Up to 12 hours of operation on one charge.
  • Continuous 400Hz and 28VDC output even while charging.
  • Recharge from standard 50/60Hz mains socket.
  • Adjustable maximum charging current from remote control for optimum charging.
  • Turbo-Charge option with 1 hour to full capacity.

Output parameters (400Hz AC power):

  • Rated output power, kVA: up to 180
  • Rated output voltage phase/line, V: 3 x 115/200
  • Output voltage frequency, Hz: 400 ± 0,01%
  • Total harmonic content THDU, %: ≤ 2.0.
  • Crest factor: 1.414±0.04
  • Load power factor: from 0.8 lagging to 0.95 leading
  • Load variation range, %: 0…100
  • Voltage regulation range, %:
    • <0.5
    • up to 30 for unbalanced (single phase) load
  • Voltage modulation, %: <1.0

Permissible overload, % :  

  • within 2h, at cosφ  =1: 100
  • within 600 s: 150
  • within 30 s: 200
  • within 10 s: 250*
  • within 5 s: 300*
  • within 2 s: 400*

*Overloads are applicable only in Static mode

Output parameters (28VDC power):

  • Nominal output voltage, V: 28
  • Output voltage stabilization accuracy, %: 0.85
  • Voltage ripple, %: <1
  • Rated output current, A: 600
  • Voltage compensation, V: 0 – 5
  • Output voltage adjustment range, V: 19 – 33
  • Permissible output current overload, A:
    • within 30 s: 1200
    • within 10 s: 1800
    • within 5 s: 2100
    • within 2 s: 2400

Input parameters:

  • Rated supply voltage, V: 3x400, PE
  • Supply voltage permitted deviation, V:  
    • Static mode: 340…460
    • Charging mode: 285…475
  • Rated supply frequency, Hz: 45…65
  • Overall efficiency at nominal condition, %: ≥ 95
  • Starting current: No, soft start

Miscellaneous:

  • Overall dimensions  W x H x D, mm: 2800 x 1560 x 1450
  • Weight, kg: ≤2000
  • Ingress protection (converter module): IP55
  • Maximum ambient temperature, º?: +50
  • Minimal ambient temperature, º?: -40
  • Relative humidity, %: 10…100
  • Audible noise at 1m distance, dB: ≤ 65