BSS - Model CAL-IEC(-S) -Partial Discharge Calibrator
Reference signal generator with a defined signal level for the calibration of partial discharge measuring instruments according to IEC 60270. Various pC range options and a version for external injection capacitors with step voltage output according to IEC 60270 available. The signal can be triggered by a TTL signal, by a photodiode, by a manual trigger button and by the remote control via fiber optic (FO) cable. In addition, it can be set to a fixed repetition rate per internal clock. The pulse generator is operated by lithium-ion battery and can be controlled remotely by FO if required.
Most popular related searches
- Reference signal for the calibration of electrical PD measurement systems
- IEC 60270 conform
- Various pC range options
- Version for external injection capacitors with step voltage output according to IEC 60270
- Lithium-ion battery-powered
- Trigger options: manual, photodiode, 100/120 Hz, 400/480 Hz, TTL, LWL