Cirris - Model CH2 -Advanced Low and High-Voltage Harness Tester
The low- and high-voltage harness tester, Cirris CH2, supports testing up to 1500 VDC and 1070 VAC. It can be expanded to 100,000 test points for increased throughput. The advanced CH2 tester can expand to up to 100,000 test points in 156-point increments. Its compact base and expansion chassis each hold up to 800 test points. Automatic low-voltage pretests detect errors before high-voltage testing begins. The CH2 is ideal for intricate wire assemblies with electrical components. It tests passive components such as resistors, capacitors, diodes, and switches. With the optional Energization Unit, it can also perform functional testing of active components like relays and sensors. Powered by Easy-Wire® software, the CH2 simplifies assembly and troubleshooting with visual connector images and step-by-step prompts.
Expandable Options for more Test Points
Each unit accommodates up to 800 test points. The system is expandable to 100,000 points with additional units for easy distribution of multiple test units around a large project.
Additionally to its test assemblies with electrical components and multiple shields and its capablity of 4-wire Kelvin measurements, it tests active components such as relays.
The Cirris CH2 supports tests of voltages up to 1500 VDC / 1070 VAC. Optional external meters for expanded measurements can be integrated.
The Cirris CH2 is optionally available with a custom front panel connector interface. The device is easily rack-mounted for larger applications.
CH2
Metric
- Dielectric withstand test, low range AC voltage max.: 100 VAC
- Insulation resistance test, low range voltage min.: 10 VDC
- Insulation resistance test, low range voltage max.: 100 VDC
- Dielectric withstand test, HV charge limit: 45 μC
- Insulation resistance test, voltage max.: 1500 VDC
- Dielectric withstand test, low range AC voltage min.: 10 VAC
- Insulation resistance test, voltage accuracy ±: 5 %
- Dielectric withstand test, HV energy limit: 35 mJ
- Dielectric withstand test, AC voltage accuracy ±: 5 %
- Dielectric withstand test, AC voltage min.: 100 VAC
- Insulation resistance test, voltage min.: 100 VDC
- Dielectric withstand test, AC voltage max.: 1070 VAC
- Dielectric withstand test, AC current limit max.: 2.5 mA
- Dielectric withstand test, max. capacitance per net 1: 30 nF
- Dielectric withstand test, AC current limit min.: 10 µA
- Dielectric withstand test, DC current limit max.: 2.5 mA
- Insulation resistance test, resistance max.: 1000 MΩ
- Dielectric withstand test, low range AC voltage tolerance ±: 5 V
- Insulation resistance test, low range voltage tolerance ±: 5 V
- Dielectric withstand test, DC current limit min.: 0.1 mA
- Insulation resistance test, resistance min.: 5 MΩ
- Dielectric withstand test, max. capacitance per net 1 voltage: 1500 VDC
- Dielectric withstand test, max. capacitance per net 5: 9.5 nF
- Dielectric withstand test, max. capacitance per net 5 voltage: 1000 VAC
- 2-wire, resistance accuracy ±: 2 %
- 2-wire, resistance accuracy resolution: 0.1 Ω
- 4-wire, resistance accuracy resolution: 0.001 Ω
- 4-wire, resistance max.: 100 Ω
- 4-wire, resistance accuracy ±: 2 %
- 4-wire, current max.: 2 A
- 4-wire, current min.: 0.002 mA
- Component test, resistors accuracy ±: 2 %
- Insulation resistance test, resistance accuracy ±: 10 %
- Component test, resistors max.: 1000 kΩ
- Component test, resistors min.: 0.1 Ω
- 4-wire, resistance min.: 0.001 Ω
- 4-wire, voltage max.: 2.5 V
- Component test, capacitors accuracy ±: 10 %
- Dielectric withstand test, low range DC voltage tolerance ±: 5 V
- Component test, capacitors accuracy resolution: 0.05 nF
- Component test, capacitors min.: 0.1 nF
- Dielectric withstand test, low range DC voltage max.: 100 VDC
- Component test, capacitors max.: 5000 µF
- Dielectric withstand test, DC voltage accuracy ±: 5 %
- Dielectric withstand test, low range DC voltage min.: 10 VDC
- Dielectric withstand test, DC voltage min.: 100 VDC
- Dielectric withstand test, DC voltage max.: 1500 VDC
- 2-wire, resistance min.: 0.1 Ω
- 2-wire, resistance max.: 1000 kΩ
- 2-wire, current max.: 10 mA
- 2-wire, current min.: 1 µA
- 2-wire, voltage max.: 2.5 V
- Power supply input: 115 / 230 V, 50-60 Hz
- Component test, twisted pairs: verifies proper pairing
- Test point interface: 96 pos. Female VME Eurocard connector-32 pos. loaded
- Test points per net max.: unlimited
- Component test, diodes: 0 to 2.5 V
- Height: 160 mm
- Depth: 442 mm
- Width: 441 mm
- Weight: 19 kg
- Test points min.: 160
- Test points max.: 100000
- DIO voltage max.: 30 V
- Digital outputs: 10
- Digital inputs: 10
Imperial
- Dielectric withstand test, low range AC voltage max.: 100 VAC
- Insulation resistance test, low range voltage min.: 10 VDC
- Insulation resistance test, low range voltage max.: 100 VDC
- Dielectric withstand test, HV charge limit: 45 μC
- Insulation resistance test, voltage max.: 1500 VDC
- Dielectric withstand test, low range AC voltage min.: 10 VAC
- Insulation resistance test, voltage accuracy ±: 5 %
- Dielectric withstand test, HV energy limit: 35 mJ
- Dielectric withstand test, AC voltage accuracy ±: 5 %
- Dielectric withstand test, AC voltage min.: 100 VAC
- Insulation resistance test, voltage min.: 100 VDC
- Dielectric withstand test, AC voltage max.: 1070 VAC
- Dielectric withstand test, AC current limit max.: 2.5 mA
- Dielectric withstand test, max. capacitance per net 1: 30 nF
- Dielectric withstand test, AC current limit min.: 10 µA
- Dielectric withstand test, DC current limit max.: 2.5 mA
- Insulation resistance test, resistance max.: 1000 MΩ
- Dielectric withstand test, low range AC voltage tolerance ±: 5 V
- Insulation resistance test, low range voltage tolerance ±: 5 V
- Dielectric withstand test, DC current limit min.: 0.1 mA
- Insulation resistance test, resistance min.: 5 MΩ
- Dielectric withstand test, max. capacitance per net 1 voltage: 1500 VDC
- Dielectric withstand test, max. capacitance per net 5: 9.5 nF
- Dielectric withstand test, max. capacitance per net 5 voltage: 1000 VAC
- 2-wire, resistance accuracy ±: 2 %
- 2-wire, resistance accuracy resolution: 0.1 Ω
- 4-wire, resistance accuracy resolution: 0.001 Ω
- 4-wire, resistance max.: 100 Ω
- 4-wire, resistance accuracy ±: 2 %
- 4-wire, current max.: 2 A
- 4-wire, current min.: 0.002 mA
- Component test, resistors accuracy ±: 2 %
- Insulation resistance test, resistance accuracy ±: 10 %
- Component test, resistors max.: 1000 kΩ
- Component test, resistors min.: 0.1 Ω
- 4-wire, resistance min.: 0.001 Ω
- 4-wire, voltage max.: 2.5 V
- Component test, capacitors accuracy ±: 10 %
- Dielectric withstand test, low range DC voltage tolerance ±: 5 V
- Component test, capacitors accuracy resolution: 0.05 nF
- Component test, capacitors min.: 0.1 nF
- Dielectric withstand test, low range DC voltage max.: 100 VDC
- Component test, capacitors max.: 5000 µF
- Dielectric withstand test, DC voltage accuracy ±: 5 %
- Dielectric withstand test, low range DC voltage min.: 10 VDC
- Dielectric withstand test, DC voltage min.: 100 VDC
- Dielectric withstand test, DC voltage max.: 1500 VDC
- 2-wire, resistance min.: 0.1 Ω
- 2-wire, resistance max.: 1000 kΩ
- 2-wire, current max.: 10 mA
- 2-wire, current min.: 1 µA
- 2-wire, voltage max.: 2.5 V
- Power supply input: 115 / 230 V, 50-60 Hz
- Component test, twisted pairs: verifies proper pairing
- Test point interface: 96 pos. Female VME Eurocard connector-32 pos. loaded
- Test points per net max.: unlimited
- Component test, diodes: 0 to 2.5 V
- Height: 6.3 in
- Depth: 17.4 in
- Width: 17.4 in
- Weight: 42 lb
- Test points min.: 160
- Test points max.: 100000
- DIO voltage max.: 30 V
- Digital outputs: 10
- Digital inputs: 10