Thermogenics Inc.
- Home
- Companies
- Thermogenics Inc.
- Products
- Thermogenics - Coil Tube Thermal Fluid ...
Thermogenics - Coil Tube Thermal Fluid Heater
Efficient, safe and economical process heat, up to 20,000,000 BTU/hour output.
Most popular related searches
burner management system
thermal fluid heater
atomized burner
gas pilot
burner management
combustion chamber
boiler shell
oil burner
process heating
gas burner
Thermal Heater Type
Forced Circulation, Multi-Coiled Tube, Forced Draft Fired.
EfficiencyUp to 84%.
Gas BurnerMulti-orificed by Thermogenics.
Oil BurnerAir Atomized by Thermogenics.
Combination BurnerAir Atomized Oil, Multi-orificed Gas by Thermogenics.
Ignition TypeElectric Spark Ignited, Interrupted Gas Pilot.
Turndown
Up to 10:1 turndown.
ConstructionRegistered to ASME and CSA requirements and Hydro approved.
SafetyProgrammed Flame Safeguard Control with Ultra Violet Flame Detection. Individual Coil Temperature Control and Outlet Temperature Limits.
Operating Pressure750ºF design temperature, up to 250 PSIG.
- No refractory combustion chamber, new membrane wall furnace.
- Redesigned combustion air blower ensures quiet operation.
- Redesigned damper blades on combustion blower provide lower excess air levels.
- Redesigned burner increases efficiency.
- Optional linkageless control provides lower turndown rates and more consistent efficiencies across the modulating range.
- 4-20 ma modulation for feedback to PLC based Lead/Lag Control.
- Complete flexibility on burner management systems.
- Solid state coil temperature system with individual temperature readouts and set points.
- Fully modulating burner with up to 10:1 turndown on Natural Gas and #2 Oil.
- Switch controls and warning devices located in a central control panel at the front of the boiler skid for ease of operation and troubleshooting.
- All coils have individual monitoring sensors.
- Quick response to load changes.
- Rapid start up from cold start.
- Long life with minimal maintenance coils designed for 1000 PSIG.
- Rear door access at floor level without disturbing refrac tory seal.
- All electrical boxes are oil/dust tight.
- All electrical conduit liquid tight.
- Separate high voltage side panel.
- Combustion air blower at floor level for ease of inspection and maintenance.
- Recirculating pump and combustion blower direct drive.
- Most service connections located at common junction point.
- Double walled boiler shell preheats combustion air and cools outer casing, thereby minimizing radiation losses.
- Optional air or water cooled pumps.
- Optional deaerator/expansion tanks.