The modularity of this platform allows it to be used in applications up to 1000V and in parallel battery applications. The BMS consists of BMU (Battery Monitoring Unit) modules, responsible for monitoring the temperature and voltage of the cells and a BMC (Battery Management Controller) that interprets, evaluates and acts on the information received by the BMU. The BMS has been designed to meet high safety standards and increase battery performance and durability through advanced SOx diagnostic algorithms.
Most popular related searches
battery monitoring system
battery management system
battery monitor
battery monitoring
battery management
battery system
battery performance
voltage management system
high voltage system
voltage management
- Cell chemistry agnostic
- BMC controls up to 63 BMU. Each BMU monitors from 7 to 16 cells
- Adaptable to single board for LV systems
- Integrated Battery Insulation monitoring (up to 10 MOhm)
- 3 Isolated battery voltage analog measurements
- Shunt (isolated) and Hall battery current sensor reading
- 4 configurable temperature sensor inputs for battery pack (BMC). Up to 16 temperature sensor inputs for cell monitoring (BMU)
- Controls 4 contactors of 1A rated (9A peak)
- HV interlock mechanism
- 4 CAN-FD connections with adjustable baud rate
- 1 Vehicle with wake up
- 1 Debug (DeveLinkSTUDIO)
- 2 Auxiliary (additional sensors)
- Sleep mode enabling low power consumption
- SoC, SoP, SoH battery diagnostics algorithms
- Error log for failure cause analysis and safe system recovery. Micro SD card available.
- Passive cell balancing (300mA)
- ASIL-D certified microcontroller for ISO26262 requirements
- Configuration, calibration, and software upgrade support with DeveLinkSTUDIO
- 1 Debug USB (same DeveLinkSTUDIO functionality)
- 4 Auxiliary digital Input/Output
- Configurable CAN Database
- 4 CAN-FD inputs available to enable parallelising batteries
- Integrated Battery isolation monitoring
- System error log for failure cause analysis
- Predictive SoH at battery level through Machine Learning Analysis