Garioni Naval - Model Keeler DS -Water Tube Steam Boiler up to 60 t/h
Boiler Section: Superior natural circulation and operational characteristics with D-Type Proven Design. Complete access to boiler drums, furnace and convention sections. Visibility thru observation ports. 100% Welded-membrane wall design based on headered construction. No use of refractory walls and seals. Allows for quicker startups / shutdowns. Extended life due to a cooler furnace environment. Lower CO emissions and optimized furnace design for ultra-low NOx. Membrane Division Wall (zero gas bypass low emissions). Completely drainable. Serrated (grooved) tube seats for tube-to-drum attachment. Fully welded gas seals throughout; for gas-tight operation. Integral soot-blowing lanes for for dirty fuels. Baffled design primary steam separation and labyrinth steam dryers. Optional systems, such as external and internal steam seperation cyclones and water drum pre-heater.
- Register Type Packaged Design
- Lower NOx and Low CO
- Low Excess Air, High Efficiency
- Adjustable Flame Shaping
- Wide Turndown and Firing Range
- Automatic Non-jam Damper Operation in
- Multi-burner Configurations
- Low Maintenance and High Reliability
- Custom Matched Modular Selection
- Standards: EN-12952/NFPA/IRI/FM
- Packaged Fuel Skids
- Scope Includes:
- Burner Register with Windbox Complete
- Combustion Air Blower With Damper. Silencor is Standard.
- (Standard Inverter Rated Motor/Optional VSD)
- Burner Management / Combustion Control System
- (Integrated into PLC Management Systems) (Autoflame)
- (Interlocked with PLC Management System) (FireEye/Honeywell)
- Fuel Skids to EN-12952/NFPA/IRI/FM
- (Rack &/or Windbox Mount)
- (Fully-metered &/or single-point designs)
- (Compact Packaged)
- (S) Double Door Enclosure w/ Independant MCC & PLC Section
- - (IP/NEMA ; (IP 54/55 or IP 40 or Ex-Proof) (O) Purge Control Unit (Ex-Proof)
- (S) Panel Air Conditioning Unit
- (S) UPS for PLC Control Section
- (S) BMS Interlocked with PLC
- (S) Touch Screen Control Panel With PLC (Optional Fail Safe PLC)
- (S) DCS/SCADA Communication Interface (Modbus/Ethernet/Profibus)
- (S) 3-Element Control System
- (S) Flow Metering with trending for Main Fuel, Steam, Feed Water
- (S) De-Salting Drum (Surface) Blow Down Control
- (S) Oxygen Trim (O2) Control (Fired Boilers Only)
- (S) Level Switches Based on Conductivity Probes (in addition to LT/Cap.
- (S) For Heavy Oils (Re-Circulation Control)
- (O) BMS Integrated into PLC (Economic Module)
- (O) Intermittent Blow-Down Control
- (O) Redundant Electro-Mechanical Reserve System (Controllers-Fuji/Yokogawa/Honeywell/Eurotherm)
- (O) De-Superheating Control (Attemperator or Diverging CV), Pressure Control Stations, Combi Stations
- (O) Automatic Soot Blowing Control (Steam or Sonic)
- Control Valves Samson or Arca or Koso / Fisher or Masonlienan
- Transmitters Fuji or Autrol / Ivensys or Honewell / Yokogawa or Rosemount
- Temp. Sensors/TT Comeco or Fuji
- Vortex Meters Krohne or Rheonik
- Gauges Nuvo Fima / Ashcroft
- Switches Danfoss or Sauter or SOR / Mercoid / Ashcroft
- Variable Speed Drives ABB or Yasakawa or Fuji / Danfoss or Schneider / LS Systems
- Level Control Switches Gestra or Mobrey / VYC or RTK / Clark Reliance
- De-Salting Control Gestra or Spirax / VYC or RTK
- Level Indicators Klinger / Bont or Diesse (LP)
- Electrical Devices GE / Terasaki or Green Power /Telemecanique or MG
- PLC System RENU or ICP-DAS (High Ambients) / Siemens or Allen Bradley or Mitsubishi
- Fixtures & Fiitings EU/USA/Japan
- Oxygen Analyzers Ametek (Land Instruments)/Fuji/Client Specific
- Valves Kitazawa or Velan / Mival / Valvole Hoffman (LP) / DHV or Equiv. (Isolation & Drains)
- Feed Pumps SIHI or KSB (HP) / Grundfoss or Nocchi (LP)
- Dosing Systems LMI (LP) / Doseuro (HP)
- Safety Valves Tyco (Kunkle) / Leser
- Sampling Stations FM (Catch’n’Grab Stations are Standard. Fully Automated Water Analysis Stations on Request)
- Optional FGR Package
- DIVERTOR, DAMPERS, GUILLOTINES, EXPANSION JOINTS
- FLUE GAS DUCTING
- Internal Lined (Insulated) in Carbon Steel With (O) SS Liners
- External Insulated/Un-Insulated in Carbon Steel, Corten or Stainless
- DEAERATORs
- Pressurised (Tray or Spray)
- Atmospheric (Spray)
- FEED WATER PUMPS
- Turbine Driven
- Motor Driven
- DOSING SYSTEMS
- STACKS
- Main and/or By-Pass
- External Insulated/Uninsulated/Lined in Carbon Steel, Corten or Stainless
- ELECTRICALS, INSTRUMENTATION AND CONTROLS
- NEMA/IP/Ex-PROOF
- CONTINUOUS EMISSIONS MONITORING SYSTEMS (CEMS)
- LADDERS & PLATFORMS
- AIR & FLUE HEATERS
- FUEL OIL HEATERS AND PUMPING SKIDS
- BLOWDOWN SYSTEMS
- SCR, SNCR, & CO Catalytic System (NOX/SOX CONTROL)
- ERECTION AND COMMISSIONINGCaldaia a tubi d’acqua fino a 60 T/H