electromagnetic-compatibility Downloads
44 downloads found
EMV 2017 is Europe's leading exhibition for Electromagnetic Compatibility. Present your products and innovations from 28 - 30 March 2017 in Stuttgart. ...
The transducer fulfi ls all the important requirements and regulations. concerning electromagnetic compatibility EMC and Safety (IEC. 1010 resp. EN 61 010). ...
GUCBIR gensets are compliant with EC mark which includes the following directives: 2006/42/CE Machinery safety. 2014/30/UE Electromagnetic compatibility. 2014/35/UE electrical equipment designed for use within certain voltage limits. 2000/14/EC Sound Power level. ...
GUCBIR gensets are compliant with EC mark which includes the following directives: 2006/42/CE Machinery safety. 2014/30/UE Electromagnetic compatibility. 2014/35/UE electrical equipment designed for use within certain voltage limits. 2000/14/EC Sound Power level. ...
GUCBIR gensets are compliant with EC mark which includes the following directives: 2006/42/CE Machinery safety. 2014/30/UE Electromagnetic compatibility. 2014/35/UE electrical equipment designed for use within certain voltage limits. 2000/14/EC Sound Power level. ...
Available in 208 – 408 Vac Technical Specification Model AHRMC 70 AHRMC 100 AHRMC 130 Rated power * 49 - 59 kVA 70 – 84 kVA 91 -109 kVA Compensation current capacity at 50/60 Hz 70 Arms 100 Arms 130 Arms System Voltage ** 480 V ( 208 - 480V) Nominal frequency** 50/60 Hz ±2% Number of phases 3 Connection type 3 phase without neutral ( TN, TT, IT) Harmonic current compensation Individual ...
The devices under test can be connected to LV or MV networks and may vary within a broad power range: small scale under 1 kW; medium scale; and large scale over several MW.In particular, the following aspects can be tested:• Interconnection and grid code compliance• Electromagnetic compatibility (EMC)• Interoperability and communication; protection• Reliability ...
ByDERlab
The transducer SINEAX U 553 (Fig. 1) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load independent DC voltage proportional to the measured value. The transducer fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in ...
The transducer SINEAX G537 (Fig. 1) converts the phase angle difference of two synchronised supplies into a load independent DC current or a load independent DC voltage proportional to the measured value. The transducer fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and ...
The transformer SINEAX I 538 (Fig. 1) converts a sinusoidal AC current into a load independent DC current or a load independet DC voltage proportional to the measured value. The transducer fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance ...
The transducer SINEAX P530/Q531 (Fig. 1) converts to active or reactive power of a single-phase AC or three-phase system with balanced or unbalanced loads. The output signal is proportional to the measured value of the active or reactive power and is either a load-independent DC current or a load-independent DC voltage. The transducer fulfils all the important requirements and regulations ...
The transducer SINEAX I552 (Fig. 1) converts a sinusoidal or a distorted AC current into a load independent DC current or a load independent DC voltage proportional to the measured value. The transducer fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict ...
The transducer SINEAX U 543 (Fig. 1) converts a sinusoidal AC voltage signal into an output signal that can serves several receiving instruments such as indicators, recorders, alarm units etc. The transducer fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in ...
The transducer SINEAX G536 (Fig. 1) measures the phase angle or power factor between current and voltage of a single or 3-phase balanced network having a sine wave form. The output signal, in the form of a load independent DC current or voltage, is proportional to the phase angle resp. power factor between the 2 measured quantities current and voltage. The transducer fulfils all the important ...
The transducer SINEAX P530/Q531 (Fig. 1) converts to active or reactive power of a single-phase AC or three-phase system with balanced or unbalanced loads. The output signal is proportional to the measured value of the active or reactive power and is either a load-independent DC current or a load-independent DC voltage. The transducer fulfils all the important requirements and regulations ...
The transducer SINEAX U 539 (Fig. 1) converts a sinusoidal AC voltage into a load independent DC current or a load independent DC voltage proportional to the measured value. The transducer fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict accordance ...
The transducer SINEAX U553 (Fig. 1) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load independent DC voltage proportional to the measured value. The transducer fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 1010 resp. EN 61 010). It was developed and is manufactured and tested in strict ...
Standards CE-conformity; Low voltage directive 2006/95/EC; Electromagnetic compatibility Conformance with EMC directive 2004/108/EC; IEC 61000-6-3; IEC 6100-6-4; IEC 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use); IEC 61643-1 (Low voltage Surge Protection Device); IEC 60269-6 (Supplementary requirements for ...
SPD´s for all communication ports ? Electromagnetic compatibility EN 61000-4, EN 55011 ? IP65 housing ? Wall-/rack mounted configuration Effective PV Monitoring requires constant, solid and traceable PV Plant monitoring data in order to determine actual performance and fulfil owner/investor expectations. ...