VIMAR
VIMAR - Model VIGAS 16 -Hot Water Boiler
FromVIMAR
Boiler with excellent parameters and top quality. Ideal for heating small family houses up to 150 m 2 and for those who care about the environment. The new design of the combustion chamber ensures preheating of both primary and secondary air, which results in perfect combustion in the entire power range from 8 to 18 kW. At the beginning of 2016, a boiler with an innovative design and new control software was launched on the market for more efficient combustion and increased boiler efficiency. The boiler is class 5 according to the EN303/5:2021 standard.
Most popular related searches
hot water boiler
combustion chamber
boiler efficiency
boiler equipment
wood chip briquetting
combustion boiler
gas powered
gas power
boiler design
- Management using the most modern AK4000 regulation, which allows you to have everything clearly under control on the graphic display
- High efficiency of the boiler up to 90.9%
- Removable primary air line for easy cleaning
- Maximum log length 370 mm
- Slanting of the walls of the tank space for easy, self-directed fuel movement towards the nozzle
- Large storage chamber up to 80 l
- Sealed tank space to reduce tar formation
- The possibility of choosing the direction of opening the door to the left or right
- Higher insulation thickness for increased efficiency
- AK 4000 regulation
- EBM pressure fan
- Flue gas thermometer Type PT1000
- Aerated concrete nozzle LAC small (5-hole)
- STB fuse
- Cleaning accessories
- Drain valve 1/2"
- Exhaust fan V25
- Release valve Honeywell TS131
- Metal adjustable legs 15 cm high
- Metal ashtray in front of the boiler
- Nominal output of the boiler : kW : 16
- Ecodesign - Commission Regulation (EU) 2015/1189 : : ?
- Boiler class according to EN 303-5:2021 (efficiency / emissions) : : 5 / 5
- Max. operating pressure : bar : 3
- Fuel : : wood up to max. humidity 20% with calorific value min. 15 MJ/kg
- Power range : kW : 8 - 18
- Efficiency: nominal/minimum : % : 90.9/90.1
- Fuel consumption at min. performance : kg/hour : 4.2
- Spare fuel : : Wood waste, chips, sawdust, sawdust briquettes up to max. humidity 20%
- Chimney draft : mBar : 0.10-0.20
- Weight of the boiler : kg : 400
- Inlet diameter : G/mm : 2"
- Outlet throat diameter : G/mm : 2"
- The diameter of the filling valve : G : ½"
- Water filling volume : l : 60
- Flue gas at rated output : °C : 150
- Flue gas at minimum power : °C : 100
- Dimensions of the filling chamber - Depth : mm : 370
- Dimensions of the filling chamber - Height : mm : 500
- Dimensions of the filling chamber - Width : mm : 380
- Dimensions of the filling hole (w-h) : mm : 435 -255
- Max. weight of fuel : kg : 20
- Filling chamber volume : dm³ : 80
- Noise : dB : 45
- Max. electrical input : W : 13.8
- Voltage/frequency : V/Hz : ~ 230V / 50Hz