transformer-isolation Downloads
42 downloads found
INPUT VOLTAGE—24 vdc nominal, 18 to 30 vdc. 10% overvoltage willnot cause damage to the equipment.RELAY CONTACT RATING—2 amperes (resistive) at 30 Vdc maximum.0.5 ampere (resistive) at 125 Vac (FM & CSA only).OUTPUT STYLE—Type "C" relay (normally open/normally closed).RESPONSE TIME—Output actuates in <0.15 second after acknowledgingan alarm command message.LON COMMUNICATION—Digital communication, ...
HPS Drive Isolation Transformers are designed to meet the rugged demands of both AC and DC variable speed drives and also to provide the required voltage change. HPS offers three lines of drive isolation transformers compliant to different levels of ...
Part Number : PS-01-V25-A40. Power : 1 kW. Transformer : Isolation Transformer. Full Load Efficiency : > 95%. ...
MTE’s SineWave Nexus filter combines the performance of a sinewave filter with our patented common mode protection technology into a single passive device. The SineWave Nexus not only cleans the PWM waveform generated by Variable Frequency Drives (VFDs), it virtually eliminates common mode voltage which causes motor bearing failures. By filtering out the damaging common mode voltage, motor ...
HELIOS C protects PSTN phone lines and equipment connected to the network against raise of ...
Galvanic isolation between the stabilizer and the main power supply. Change the voltage grade. Improve the balance of the phase voltage and provide a steady neutral point. Protection from voltage surge and cancel the triplen ...
HELIOS D protects ADSL phone lines and equipment connected to the network against raise of ...
Single phase transformer with a high degree of electrical isolation between primary and secondary. It incorporates one or more electrostatic copper shields as additional separation between windings. It offers a high level of attenuation and filtering of electrical disturbances. It also improves the possible noise present in the electrical network supply. ...
ATO single phase & three phase isolation transformers are dry-type transformers which made of high-quality materialsand advanced technology, is designed to step up / step down the voltage as per requirements and can be directlyinstalled and used in loads of different properties. Our isolation transformers available with 2 shapes: Open type thatwithout the enclosure and protected type with ...
For indoor/outdoor dry-type transformers which utilize DH series, NH series CN Series or NJ1, NJ2, NJ3, NJ4 type enclosures. This manual covers the recommendations for the installation, operation and maintenance of dry-type low voltage transformers. It is emphasized that these abbreviated instructions should be used in conjunction with all local and National codes and should be referenced ...
Sampling Loops are used to properly tune and maintain AM directional antenna arrays. The ERI sampling loop provides an accurate means to sample radio frequency energy in towers of a directional AM antenna array. The 601 Series sampling loops provide individual tower current samples for an antenna phase monitor, in directional AM antenna arrays. Sampling loops are always used to provide the ...
This series of inverters is capable of operating at 208 VAC, 240 VAC, 480 VAC, and 600 VAC and comes standard with AC and DC disconnects, transformer isolation, LCD, and monitoring gateway. They also contain a lightweight power stage making it easily serviceable. ...
Isolated online UPS provides the cleanest power in the most demanding conditions. The TX90 galvanic isolation transformer prevents common mode noise which is left exposed by typical transformerless online designs. Isolated online applications include retail, industrial environments, laboratories, and any installation with ...
The isolating transformers are specifically designed to meet the main requirements of the TLC plant operators, that is to ensure continuity of operation to transmitter plants usually installed in remote areas, exposed to atmospheric discharges and connected to electric lines subject to important voltage drops. All the models are characterized by a low output impedance and are unaffected by load ...
The 16SCT000 is an IGBT/MOSFET gate driver (15V nominal Vg) chip to control the conduction state of a high-side switch from the secondary of a small high voltage isolation transformer. The 16SCT000 will drive the gate of the HV switch above the emitter/source while the secondary winding of the transformer drives the complementary input signals. Upon cessation of the input drive signals, the ...
The Precision Electronically Compensated Voltage Transformer CMR-U is a universal small-sized electronically controlled precision voltage transformer for galvanically isolated voltage transmission. ...
ELIT M Series inverters are devices forming line voltage from 12V, 24V and 48V battery voltages used in daily life and business life. Thanks to practical uses, output isolation transformer structures and charging facilities, these units are used safely in land and sea vehicles and open spaces. Because generates output voltage in the form of Sinusoidal, they offer trouble-free solution to all ...