Refine by
Combustor Articles & Analysis: Older
32 articles found
However, despite the low concentration of mixed hydrogen, co-firing hydrogen and natural gas still encounter the severe challenge of ensuring a stable ratio of mixed gases before entering the combustors. To ensure safe and stable operation at regulated temperature and pressure conditions, stringent demands are placed on the precision and steadiness of hydrogen concentration when ...
Introduction 310 stainless steel is an austenitic stainless steel developed for use in high temperature corrosion resistant applications. Typically used in coal combustors, radiator tubes, steam boilers, thermowells, burners, combustion chambers, food processing equipment, and cryogenic hardware. 310S is the low carbon version of the stainless steel. ...
Proposed SolutionAfter careful analysis of the facility’s process, maximum possible exhaust volume, and need to come on-stream quickly, Pollution Systems’ engineering experts recommended a Horizontal Enclosed Flare (aka Combustor) for the abatement of waste acid gas from the amine unit. Thermal destruction of waste gases is a common control technique to destroy HAPs, VOCs and/or ...
The turbines are in the process of being retrofitted to utilize a state-of-the-art dry-low-NOx combustor design that achieves minimal NOx emission ...
The turbines combust exclusively pipeline natural gas and utilize a dry low-NOx combustor to minimize NOx emissions. The turbines drive a 170 MW generator for production of electrical power. ...
By replacing the generators with the low emissions Mercury™ 50, which utilizes an ultra-lean premix combustor design and produces less than 5 ppmv NOx, the hospital was able to generate $4.2 million dollars in emissions offset credits. ...
By replacing the generators with the low emissions Mercury™ 50, which utilizes an ultra-lean premix combustor design and produces less than 5 ppmv NOx, the hospital was able to generate $4.2 million dollars in emissions offset credits. ...
In 2014, Powerphase installed a Turbophase system consisting of two Turbophase modules, at a cogeneration plant in the U.S. The Morris Cogen plant is a 177 MW combined-cycle gas facility located within the Equistar Chemicals petrochemical plant in Morris, IL. The Morris plant has a single pressure steam turbine (ST) (625 psig/750°F) rated at 57 MW, and three GE MS6001B, PG6561 gas turbines ...
PROJECT DETAILS Location: RockyMountains FlowRate: 1.75MMSCFD InletPressure: 9”WC Heating Value: 227 BTU/SCF Application: Coal Mine Methane Recovery Aereon’s GHOST Series Enclosed Combustor AB-200 was purchased by the client to recover methane from an abandoned coal mine in order to earn hydrocarbon credits. ...
PROJECT DETAILS Location: Texas Panhandle Max inlet flow rate at 1,600 Btu/ft3 AB-20: 36.0 MSCFD Rated heat capacity: 2.4 MMBTU/hr Inlet Temperature: < 130 °F Minimum Pressure required for operation: 4 oz/in2 Smokeless flow rate: 0 -100% of design flowrate meets Ringelmann1 Destruction Rate Efficiency: 98% DRE Aereon’s Ghost Series AB20 Enclosed ...
Project Details Location: Rosa, CA & Dexter, MI Max Heat Release: 2.4 MMBTU/HR Application: Food Services (Brewery) Customer purchased a flare system designed by a competitor, and upon installation, determined that they had issues lighting the burner. Detailed analysis of the design revealed that the burner design was not appropriate for the application. AEREON’s Service & ...
Project Details Location: Mid-Continent Heat Capacity: 18.4 MM BTU/hr Inlet Pressure (AP): 2 psig Aereon's Ghost Series enclosed combustors are designed to burn waste gas in a smokeless application. This customer in the Mid-Continent region is using 6 combustors as an emergency backup to the sales line. ...
PROJECT DETAILS Location: Permian Basin Flow Rate LP: 20.0 MSCFD LP Inlet Pressure (ΔP): 4 oz/in.2 Smokeless %: 100% Pilot & Controls: ProFire2100 Solar Package: No Electricity Required Installed Year: 2017 Aereon’sGhost Series Enclosed Combustor (EPA Certified for Quad O Compliance) is used to burn off waste natural gas from a low pressure tank. The ...
Customer used multiple flares along with a combustor to be able to accommodate high and low pressures coming from multiple sources. ...
By combining these technologies into a single skid mounted package the technologies used for the Ghost Series combustor and Momentum HP flare allows for 100% smokeless performance without requiring any utilities for operation due to the solar ignition package. ...
System Description The final solution proposed was a ‘four chamber – one unit’ solution. The pre-combustor contained the gas burner firing sub-stoichiometrically to reduce NOx formation. ...
Some key issues that everyone should consider include: Optional testing of the Combustor can be done by the manufacturer following rules in NSPS 0000 (60.5413): Tested Combustors must be listed in the EPA list of tested devices. ...
The products and services available can be divided into four categories: burners, combustors, injection systems and engineering & service. The vertical and horizontal burners and combustors are used for sulphur, spent acid and acid gas; waste gas and waste air, waste water, hazardous and special waste liquids and pasty waste fluids. ...
The purpose of this study was to investigate the effect of bed height on the quality of rice husk ash in a 210–mm diameter pilot scale fluidised bed combustor. The degree of rice husk burning in the fluidised bed could be deduced from the temperature of the combustor and the particle size of the resulting ash. ...
The investigated main components of the engine are the compressor, the combustor, the gas generator, the power turbine and the exhaust. Exergetic parameters, along with exergo–economic parameters, have been calculated for each engine component.Keywords: turboprop engines, exergy analysis, exergoeconomics, transport aircraft, aviation industry, operating costs, fuel consumption, ...