burner controller Articles
-
High Temperature Combustion of Biogas
High Temperature Combustion of Biogas Efficient combustion of biogas Controlled and concealed combustion Combustion temperature > 900°C Residence time more than 0.3 s Insulated combustion chamber High safety standard The HOFGAS® - IFL4c high temperature flare provides safe and environmentally-friendly combustion of biogas. The exhaust gas emissions meet the stringent requirements. ...
-
Royal Darwin Hospital Contract Report Case Study
As part of a larger infrastructure upgrade project at Royal Darwin Hospital, CCM Energy Solutions were elected by the primary contractor (O'Donnell Griffin) to supply two new Limpsfield high-efficiency burners for the two main John Thompson boilers which provide steam to the hospital. In addition, new Autoflame Mk7 combustion control systems were incorporated into the design, along with in-situ ...
By Limpsfield
-
How to Achieve Precise Air-Fuel Ratio Control in Burner Control Applications
Mass flow control is all around us. One common application for industrial mass flow control is air-fuel ratio control of burners in industrial heating processes for manufacturing and other industries. For burner control in manufacturing, precise mass flow control of the air-fuel ratio to the burner keeps melt temperatures constant which produces quality products including glass, metals, and ...
-
The “Tipping” Point of High Turndown Ratios: How much of a good thing is too much?
Boilers used for domestic water and space heating are one of the highest energy consumers in residential and commercial facilities. After the global energy crisis in the 1970s, higher fuel prices prompted the search for solutions to reduce energy consumption. Back then, conventional steam boilers were the only option available. However, these boilers were very inefficient (due in part to the ...
-
Charles Darwin High School Contract Report Case Study
A no obligation survey was performed free of charge to determine how efficiently the plant was operating. A report was provided to the school outlining efficiency and emissions levels, highlighting where savings could be made and recommendations to achieve the savings. Based on the information collected during the survey, a quotation was prepared for the customer. This included the supply of 3 ...
By Limpsfield
-
5000Nm3/h HT Flares in Sao João, Brazil
Type HOFGAS®-Efficiency 5000 Performance 3x 5,000 Nm3/h, 75,000 KW Location Sao João (BR) Technical requirements Surplus combustion of 15,000 Nm3/h landfill gasCompliance with the UNFCCC regulationsHigh temperature combustion at 1,000-1,200°CHolding time ≥ 0.3s HOFSTETTER solution concept Use of 3 HOFGAS®- Efficiency 5000 high temperature flares. These are the largest ...
-
Alliance Oxidizer Advantages
The Alliance Corporations Oxidizer product line has a lot of design advantages compared with standard Regenerative Thermal Oxidizers. - Proven 2- and 3 bed Regenerative Thermal Oxidizer Design - 99% plus VOC Destruction Efficiency - Up to 97% Thermal Efficiency - Up to 30% fuel savings with proven natural gas injection - Low NOx burner operation - In-house design, programming and ...
-
E.ON Benelux power station Maasvlakte, Rotterdam - Case Study
Next Generation Power Production E.ON’s new Maasvlakte power station also known as MPP3 is built in the harbour of the Dutch metropolis Rotterdam. The modern supercritical hard coal fired unit with a capacity of 1100 MW is expected to have a thermal efficiency of more than 46 percent. The new plant built in the vicinity of the existing Maasvlakte station is designed as cogeneration plant ...
-
TPV History from 1990 to Present & Future Trends
Abstract. Herein, the history of TPV at JX Crystals over the last 15 years is described. Our focus has been on commercial application for TPV components and systems. JX Crystals began as a spin off company when the inventors of the GaSb cell left Boeing with a license to make that cell at JX Crystals. We recosnized that III-V IR sensitive cells such as the GaSb cell were enabling for TPV systems. ...
-
Monitoring Air/Fuel Mixtures in Glass and Glass Fiber Manufacturing case study
Measurement of Premix Gas. To produce the desired flame in a glass forehearth or when making fiberglass (glass fiber) insulation, an air/fuel pre-mixer is used. The pre-mixer combines compressed natural gas or propane with air and this mixture is then piped to the process burners At the burner, a fuelrich or fuel-lean flame is produced depending on the air/ fuel ratio selected. In many ...
-
Learn to Purchase a Coconut Shell Charcoal Making Machine
You can discover learning to make your very own charcoal by utilizing an electric powered charcoal making machine. There are several benefits to owning one of these machines. When choosing your coconut shell charcoal making machine, you will need to consider the quantity of cylinders that it may hold. If you would like make enough charcoal for a lot of burners consistently, then this machine with ...
-
Gas Fired Oven
INDUSTRIAL GAS FIRED OVEN CONSTRUCTION An industrial Gas Fired Oven is typically of steel construction, comprised of inner and outer shells of sheet steel panels, separated by 4” thick, 6 lb/ft3 density mineral wool insulation. The panels are constructed as to minimize metal-to-metal contact between inner and outer shells and reduce heat flow from oven chamber to the exterior surface. ...
-
Ergon, Inc. - 4.72 MW CHP System - Case Study
Quick Facts LOCATION: Vicksburg, Mississippi MARKET SECTOR: Crude Oil Processing FUEL: Natural Gas MAX CAPACITY: 4.72 MW IN OPERATION SINCE: 1994 EQUIPMENT: Solar 60 Gas Turbine Ideal Electric Co. Generator VolcanInternational Waste Heat Boiler Economizer and Exhaust System Davis Combustion Systems Duct Burner Effox Diverter Valve USE OF WASTE HEAT: Create Steam for Refinery YEARLY ...
-
Akzo Nobel Contract Report Case Study
Akzo Nobel, a global paints and coatings manufacturer with operations in over 80 countries, were seeking sustainable methods of reducing their Slough production plant’s annual emissions, as well as its fuel and running ...
By Limpsfield
-
Design for the Future
Our newest bespoke multi-chamber pet cremation furnace has been designed to match our client’s specific needs, not just in the here and now, but also in the future. When this client first contacted us they had very precise ideas about what they wanted their new pet cremator to achieve in order to boost the performance and efficiency of their pet crematorium. The reason that they came to us ...
-
Experts in combustion control - Expert Paper
Fired heaters are integral to hydrocarbon processing (HP). Specifically designed for the reaction of fuel and air to produce extremely high gas temperatures, heaters transfer this energy to potentially highly flammable process fluids via heat exchangers. They consume large quantities of fuel, produce large quantities of emissions and are a potential safety hazard to personnel and plant. However, ...
-
Benz Air Engineering Engineering Steam Efficiency - Case study
The following is a case study of a tomato processing plant located in Woodland, California. The facility produces canned tomato products. The steam boiler plant provides steam for process loads. The boiler plant contains five high-pressure steam boilers. Our case study is the retrofit for Boiler #6, Trane-Murray, water-tube boiler of 150,000 lb. per hour rated capacity (capacity is limited to ...
-
CEB 800 CA Enclosed Flare System - Case Study #170104
Project Details Location: Oxnard,CA FlowRate: 25.7MMBTU/HR InletPressure: >1psig Heating Value: 1220 BTU/SCF INFO: Oil Production Tank Vapors INFO: BACT required by AQMD INFO: Expansion to 39MMBTU/HR Aereon’sCertified Ultra Low Emissions Burner (CEB) technology is Best Available Control Technology (BACT) approved for Air Quality Management Districts (AQMD) throughout ...
-
Flow Energy Management: 3 Killer Apps to Lower Energy Costs
More and more, buzz words like “flow energy” or “flow energy management” have become prevalent as companies grapple to control costs, reduce energy use, and comply with government regulations—all while trying to increase profitability. But what are flow energy and flow energy management? Why should you care? In this three-part series, we will: Explore what flow ...
-
Solvay Specialty Polymers - 8 MW CHP System - Case Study
Quick Facts LOCATION: Marietta, Ohio MARKET SECTOR: Chemical CHP GENERATING CAPACITY: 8 MW PRIME MOVER: Solar Taurus 70 gas turbine FUEL: Natural Gas HEAT RECOVERY EQUIPMENT: 150,000 lb/hr HRSG with fresh air firing capability Two 80,000 lb/hr package boilers HEAT RECOVERY RATE: Up to 150,000 lb/hr of 300 psig process steam USE OF THERMAL ENERGY: Process heating ENVIRONMENTAL CONTROLS: ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you